Skip to main content
Schneider Electric LC1K1201FC7 — Contactors

Schneider LC1K1201FC7 TeSys K Contactor, 12 A AC-3, 127 V Co

MPNLC1K1201FC7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 12 A, 1 NC aux, 127 V AC coil, obsolete.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1K1201FC7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys

Ratings & Performance

LC1K1201FC7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-1 AC-4 AC-3

Contacts & Poles

LC1K1201FC7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1K1201FC7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

Mechanical

LC1K1201FC7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K1201FC7 is a TeSys K contactor — a compact three-pole control contactor rated for 12 A in AC-3 duty (motor switching) at up to 440 V, with a 127 V AC coil and one normally closed auxiliary contact built in. Its motor power ratings span 3 kW at 220…230 V AC up to 5.5 kW at 380…415 V and 440 V, and 4 kW at 480 V, 500…600 V, and 660…690 V — all at 50/60 Hz, covering common global line voltages. The utilisation categories include AC-1 (resistive), AC-3 (squirrel-cage motor starting/running), and AC-4 (plugging/inching), so it handles both standard motor loads and more demanding reversing or jogging applications.

The 12 A AC-3 rating at ≤440 V is the headline motor-switching current — it determines the largest standard induction motor this contactor can start and stop repeatedly without exceeding thermal limits. Heat dissipation is 1.3 W, which is low enough that no special ventilation is needed in a standard IP2X enclosure, but it should be factored into panel thermal calculations when multiple contactors are ganged. Flame retardance meets UL 94 V1 and NF F 16-101/102 requirements, so the housing materials are self-extinguishing — relevant for rail and industrial control panels that must pass fire-safety inspections.

Frequently asked questions

What are the key ratings I need to check for fit?

The critical ratings are 12 A in AC-3 duty at ≤440 V, a 127 V AC coil, and motor power up to 5.5 kW at 380…415 V or 4 kW at 480 V. The utilisation categories cover AC-1, AC-3, and AC-4.