Skip to main content
Schneider Electric LC1K1201J7 — Contactors

TeSys K LC1K1201J7 Contactor, 12 A AC-3, 12 V AC Coil

MPNLC1K1201J7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 12 A, 1 NC auxiliary contact, 12 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K1201J7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K1201J7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-4 AC-1
LC1K1201J7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K1201J7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K1201J7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K1201J7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 3 kW at 220...230 V AC 50/60 Hz 5.5 kW at 380...415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 12 A at 16 A (at 10 MOhm for signalling circuit

Product details

The LC1K1201J7 is a TeSys K three-pole contactor from Schneider Electric, rated for control applications with a 12 V AC coil. It switches motor loads up to 12 A in AC-3 duty (≤440 V) and handles resistive loads up to 20 A in AC-1.

For a 3-phase motor on 480 V, this contactor handles up to 4 kW; at 380–415 V it's good for 5.5 kW. The 12 V AC coil means it pulls in from a control transformer, not a DC bus — verify your control voltage before wiring. Heat dissipation is 1.3 W, negligible for panel thermal budgeting.

Frequently asked questions

What is the depth of this contactor?

The depth is 57 mm. Width is 45 mm, height is 58 mm — a compact footprint that fits standard DIN-rail enclosures without crowding adjacent devices.

What compliance documentation is available?

The contactor meets UL 94 V1 flame retardance and NF F 16-101/102 railway standards. Standard Schneider documentation (datasheet, certificate of conformity) covers these approvals. RoHS and REACH compliance is typical for TeSys K products but should be confirmed against the specific batch or date code on the unit sourced.

MPN
LC1K1201J7