Skip to main content
Schneider Electric LC1K12103E7 — Contactors

Schneider TeSys K LC1K12103E7 Contactor, 3P, 12A AC-3, 48V A

MPNLC1K12103E7
Active

Schneider Electric TeSys K contactor, LC1K12103E7, 3-pole, AC-3 ≤440 V 12 A, 1 NO auxiliary contact, 48 V AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12103E7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K12103E7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-4 AC-1
LC1K12103E7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K12103E7 — Environmental
ParameterValue
Flame retardanceV1 UL 94 Requirement 2 NF F 16-101 Requirement 2 NF F 16-102
LC1K12103E7 — Mechanical
ParameterValue
Width1.8 in (45 mm)
Height2.3 in (58 mm)
Depth2.2 in (57 mm)
LC1K12103E7 — Other specifications
ParameterValue
Motor power4 kW 480 V AC 50/60 Hz 4 kW 500...600 V AC 50/60 Hz 4 kW 660...690 V AC 50/60 Hz 3 kW 220...230 V AC 50/60 Hz 5.5 kW 380...415 V AC 50/60 Hz 5.5 kW 440 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 12 A at 16 A (at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 122 °F (50 °C) - 1 s for power circuit 105 A 122 °F (50 °C) - 5 s for power circuit 100 A 122 °F (50 °C) - 10 s for power circuit 75 A 122 °F (50 °C) - 30 s for power circuit 55 A 122 °F (50 °C) - 1 min for power circuit 50 A 122 °F (50 °C) - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 122 °F (50 °C) - >= 15 min for power circuit

Product details

Its utilisation categories cover AC-3 (squirrel-cage motors: starting, stopping during running), AC-4 (plugging, inching), and AC-1 (resistive heating, lighting). The 20 A rated operational current applies across these categories, but the AC-3 rating that matters for motor duty is 12 A at ≤440 V — meaning it can handle a 5.5 kW motor on a 380–415 V supply, or 4 kW on 480 V. The coil is 48 V AC, so it pulls in cleanly on a standard 48 V control transformer. With 1 NO auxiliary contact built in, it can self-latch or signal a PLC input without an extra add-on block. Heat dissipation is 1.3 W — negligible in a crowded panel, but worth noting if you're stacking dozens on a DIN rail.

The 20 A figure is the general-purpose thermal current (Ith), which applies to resistive loads in AC-1 duty. For motor applications, always size by the AC-3 rating, not the higher Ith number. Short-time withstand current (Icw) is 115 A for 1 second on the power circuit — enough to ride through a start-up inrush or a brief fault without welding the contacts. The signalling circuit (auxiliary contact) handles 110 A for 100 ms. Flame retardance meets V1 per UL 94, plus NF F 16-101 and NF F 16-102 requirements — relevant for rail and transit applications where fire safety is specified. Dimensions are compact: 2.3 in high, 1.8 in wide, 2.2 in deep. That 57 mm depth fits standard shallow enclosures and leaves room for wiring ducts in front of the contactor.

Frequently asked questions

What are the key ratings I need to check for fit?

The critical rating is AC-3 at ≤440 V: 12 A, which corresponds to a 5.5 kW motor at 380–415 V. The coil is 48 V AC. The contactor has 3 poles (all NO) and 1 NO auxiliary contact. Dimensions are 2.3 x 1.8 x 2.2 in.

How do I source this obsolete contactor?

Since it is obsolete, standard distribution does not carry it. We source it through independent surplus channels on a quoted-to-order basis. Submit an RFQ with your quantity and target price, and we will respond with availability.

MPN
LC1K12103E7