Skip to main content
Schneider Electric LC1K12103K72 — Contactors

TeSys K LC1K12103K72 Contactor, 3P, 12 A AC-3, 100 V AC Coil

MPNLC1K12103K72
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 12 A, 1 NO auxiliary, 100 V AC coil, 4 kW at 480 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12103K72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K12103K72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-1 AC-4 AC-3
LC1K12103K72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K12103K72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K12103K72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC1K12103K72 is a 3-pole contactor rated for AC-3 switching at 12 A up to 440 V, with a built-in 1 NO auxiliary contact and a 100 V AC coil. It handles motor loads up to 4 kW at 480 V and 5.5 kW at 380–415 V, making it a fit for small pumps, fans, and conveyors in control panels.

The 12 A AC-3 rating is the motor-switching current — the real-world number that governs whether this contactor holds in across starting inrush. At 480 V it carries 4 kW, at 380–415 V it carries 5.5 kW. The AC-4 category also covers plugging and inching duty, so it can handle reversing or jogging applications within the same current envelope. Coil technology uses a built-in bidirectional peak-limiting diode suppressor, which means the coil snubber is integrated — no external flyback diode needed across the coil terminals. This simplifies wiring and reduces panel assembly time. Flame retardance is rated V1 per UL 94 and also meets NF F 16-101 and NF F 16-102 Requirement 2, which is relevant for rail or transit applications where fire-smoke-toxicity standards apply.

The 45 mm width and 58 mm height fit standard DIN-rail enclosures alongside overload relays and terminal blocks.

Frequently asked questions

What motor power can this contactor switch at common voltages?

At 480 V AC it switches 4 kW; at 380–415 V it switches 5.5 kW; at 220–230 V it switches 3 kW. Also rated 4 kW at 500–600 V and 4 kW at 660–690 V.

Does the coil need an external suppression diode?

No. The coil has a built-in bidirectional peak-limiting diode suppressor, so no external flyback diode is required across the coil terminals.

What flame retardance standards does it meet?

V1 per UL 94, and also Requirement 2 per NF F 16-101 and NF F 16-102, which are rail/transit fire-safety standards.

MPN
LC1K12103K72