Skip to main content
Schneider Electric LC1K12105M72 — Contactors

Schneider TeSys K LC1K12105M72 Contactor, 3P, AC-3 12A, 220-

MPNLC1K12105M72
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440V 12A, 1 NO auxiliary, 220-230V AC coil, built-in bidirectional peak limiting diode suppressor.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12105M72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K12105M72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-1 AC-3
LC1K12105M72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K12105M72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K12105M72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K12105M72 is a TeSys K three-pole contactor rated for AC-3 duty at 12 A up to 440 V, with a 220-230 V AC coil. It handles motor loads up to 4 kW at 480 V AC, 5.5 kW at 380-415 V, and 3 kW at 220-230 V — so it covers common three-phase motor sizes across North American and European voltage standards. Built-in bidirectional peak limiting diode suppression on the coil means you don't need an external snubber for inductive kickback — one less part to panel-mount and one less wiring step.

At 1.3 W heat dissipation, this contactor adds negligible thermal load to a cabinet — you can pack it tight without worrying about derating adjacent components. Rated for AC-1 (resistive), AC-3 (squirrel-cage motors), and AC-4 (plugging/inching) duty — the AC-3 figure governs most conveyor, pump, and fan starts; the AC-4 rating matters if the application reverses or jogs the load frequently. Flame retardance to UL 94 V1 and NF F 16-101/-102 means the housing self-extinguishes — relevant for rail, marine, and any panel subject to fire-safety inspection.

Frequently asked questions

What motor power can this contactor handle?

It handles 5.5 kW at 380-415 V AC, 4 kW at 480 V AC, 4 kW at 500-600 V, and 3 kW at 220-230 V — all at 50/60 Hz. The AC-3 rated operational current is 12 A at ≤440 V.

Does this contactor include coil suppression?

Yes, it has a built-in bidirectional peak limiting diode suppressor across the coil — no external flyback diode or RC snubber needed.

What are the physical dimensions for panel layout?

Width 45 mm, height 58 mm, depth 57 mm — fits standard DIN-rail mounting and leaves room for adjacent devices in a motor starter assembly.

MPN
LC1K12105M72