Skip to main content
Schneider Electric LC1K12106FLS207 — Contactors

Schneider TeSys K LC1K12106FLS207 Contactor, 12A AC-3, 110V

MPNLC1K12106FLS207
Obsolete

Schneider Electric TeSys K series, contactor LC1K12106FLS207, 3-pole, AC-3 ≤440 V 12 A, 1 NO auxiliary contact, 110 V DC low consumption coil with integral suppression, rail or plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12106FLS207 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC1K12106FLS207 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-3e AC-1 AC-4
LC1K12106FLS207 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K12106FLS207 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV0 conforming to UL 94
LC1K12106FLS207 — Approvals
ParameterValue
StandardsBS 5424 IEC 60947 NF C 63-110 VDE 0660 IEC 60077-1 IEC 60077-2 EN 45545: R22 HL3 EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
LC1K12106FLS207 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric TeSys K LC1K12106FLS207 is a 3-pole contactor rated for motor control under AC-3 duty at 12 A up to 440 V, with a 110 V DC low-consumption coil that includes an integral suppression device. It also carries AC-1, AC-3e, and AC-4 utilisation categories, so it handles resistive loads and mixed motor duties beyond the standard AC-3 curve. The 1 NO instantaneous auxiliary contact is built in, saving a separate aux block on simple circuits.

The electrical durability at 1.3 Mcycles under those same AC-3 conditions tells you the switching life before the main poles wear out. For resistive loads (AC-1), it carries 20 A and delivers 0.3 Mcycles. The mechanical durability of 30 Mcycles far exceeds the electrical life, so the coil and mechanism outlast the contacts in normal motor duty. The 110 V DC coil draws 1.8 W hold-in power and has a wide operational voltage range of 0.7 to 1.3 Uc, with dropout below 0.1 Uc. That means it stays pulled in through moderate supply dips but drops out cleanly on a hard undervoltage. The integrated suppression eliminates the need for an external flyback diode or RC snubber across the coil — one less part on the BOM and one less wiring step. Minimum switching capability is 5 mA at 17 V for the signalling circuit, so the auxiliary contact can reliably switch PLC-level dry signals, not just power loads. The signalling circuit is rated for frequencies up to 400 Hz, which covers most control transformer and DC-DC converter outputs.

At 45 mm wide, 58 mm tall, and 57 mm deep, it fits a standard panel footprint and leaves room for a thermal overload relay on the same rail. The power circuit uses lugs-ring terminals with an external diameter of 7 mm, torqued to 0.8–1.3 N·m using a 3.2 mm flat or Philips No. 2 screwdriver. The IP20 finger-safe protection (per VDE 0106) means it's suitable for enclosed panels where operators reach in for maintenance.

Frequently asked questions

What are the key ratings for this contactor?

The key ratings are AC-3 motor duty at 12 A up to 440 V, a 110 V DC coil with 1.8 W hold-in power, 1 NO auxiliary contact, mechanical durability of 30 Mcycles, and electrical durability of 1.3 Mcycles at AC-3 12 A.

What compliance standards does this contactor meet?

It meets IEC 60947-4-1 and -5-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, EN 45545 (R22 HL3) for rail, and IEC 60077-1/2. The housing is V0 rated per UL 94 for flame retardance.

What is the minimum switching capability of the auxiliary contact?

The auxiliary contact can switch down to 5 mA at 17 V for signalling circuits, making it suitable for PLC-level dry contact inputs.

MPN
LC1K12106FLS207