Skip to main content
Schneider Electric LC1K12107D72 — Contactors

Schneider TeSys K LC1K12107D72 Contactor, 12 A AC-3, 42 V Co

MPNLC1K12107D72
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 12 A, 1 NO aux., 42 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K12107D72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K12107D72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-1 AC-4 AC-3
LC1K12107D72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K12107D72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC1K12107D72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K12107D72 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 3 kW at 220...230 V AC 50/60 Hz 5.5 kW at 380...415 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Heat dissipation1.3 W
Range of productTeSys K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current20 A (at 12 A at 16 A (at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit 25 A 50 °C - >= 15 min for power circuit

Product details

The Schneider Electric LC1K12107D72 is a TeSys K three-pole contactor rated 12 A in AC-3 duty at ≤440 V, with a 42 V AC coil and one normally open auxiliary contact. The built-in bidirectional peak-limiting diode suppressor handles coil transients without external snubbing.

Motor power coverage

This contactor switches motor loads up to 5.5 kW at 380–415 V AC 50/60 Hz, 4 kW at 480 V and 500–600 V, and 3 kW at 220–230 V. The 660–690 V rating also carries 4 kW.

Heat dissipation is 1.3 W, so no special ventilation is required in a typical control panel.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current is 12 A in AC-3 at ≤440 V, with a 42 V AC coil. Motor power ranges from 3 kW at 220–230 V up to 5.5 kW at 380–415 V. The contactor has three NO main poles and one NO auxiliary contact.

How do I source this obsolete part?

We hold last-time-buy stock and can quote against an RFQ. Submit a request with your quantity and target delivery window.

MPN
LC1K12107D72