Skip to main content
Schneider Electric LC1K16015C72 — Contactors

Schneider TeSys K LC1K16015C72 Contactor, 16 A, 36 V AC Coil

MPNLC1K16015C72
Active

Schneider Electric TeSys K contactor, LC1K16015C72, 3-pole, AC-3 16 A at ≤440 V, 36 V AC coil with built-in bidirectional peak limiting diode suppressor.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1K16015C72 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K16015C72 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1
LC1K16015C72 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K16015C72 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94
LC1K16015C72 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K16015C72 is a TeSys K contactor, 3-pole, rated 16 A in AC-3 utilisation category at ≤440 V, with a 36 V AC coil. The built-in bidirectional peak limiting diode suppressor handles coil suppression internally, so you don't need an external snubber across the coil terminals. Motor power capability spans 4 kW at 480 V AC up to 7.5 kW at 380–415 V AC, 50/60 Hz. That covers common European and North American line voltages in a single part.

The 16 A AC-3 rating is the motor-switching current at ≤440 V — that's the number that governs real motor loads, not the higher AC-1 resistive rating. Heat dissipation is 1.3 W per pole, so total 3.9 W through the enclosure. That's low enough for a sealed panel without forced ventilation, but check the thermal curve if you're grouping multiple contactors in a small enclosure. Flame retardance V1 per UL 94 means the housing self-extinguishes within 30 seconds of a flame source removal — standard for panel-mounted control gear.

The 1 NC auxiliary contact is built in, so you get a feedback signal for the PLC or a seal-in circuit without adding a separate block. Terminal numbering follows the standard IEC 60947-4-1 scheme.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current is 16 A in AC-3 at ≤440 V. Motor power ranges from 4 kW at 480 V up to 7.5 kW at 380–415 V, 50/60 Hz. Coil is 36 V AC with a built-in bidirectional peak limiting diode suppressor. Dimensions: 45 mm wide, 58 mm high, 57 mm deep.

What is the closest alternative to LC1K16015C72 in the TeSys K family?

Within the TeSys K range, the closest sibling would be a variant with a different coil voltage or auxiliary contact configuration. For a 36 V AC coil with 1 NC auxiliary, this is the exact order code; no pin-compatible drop-in exists with a different coil voltage without rewiring.

What compliance documentation is available for this part?

The contactor carries UL 94 V1 flame retardance rating. As a Schneider TeSys K product, it is designed to meet IEC 60947-4-1 and relevant UL/CSA standards. RoHS and REACH declarations are available from the manufacturer upon request.

MPN
LC1K16015C72