Skip to main content
Schneider Electric LC1K16016M7 — Contactors

Schneider LC1K16016M7 TeSys K Contactor, 16 A AC-3, 220-230

MPNLC1K16016M7
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 16 A, 1 NC aux., 220...230 V AC coil, compact 45 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K16016M7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K16016M7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1
LC1K16016M7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K16016M7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94
LC1K16016M7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K16016M7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current16 A at 20 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The Schneider Electric LC1K16016M7 is a TeSys K series contactor — three-pole, 16 A rated operational current in AC-3 utilisation category (motor switching) at voltages up to 440 V, with a 220...230 V AC 50/60 Hz coil and one normally-closed auxiliary contact built in. The AC-3 rating is the one that matters for motor loads: it means the contactor is tested and rated to switch inductive motor currents up to 16 A, making it suitable for controlling a 7.5 kW motor on a 380...415 V supply or a 5.5 kW motor at 440 V, for example. The motor power table covers a wide voltage range — from 4 kW at 220...230 V up to 7.5 kW at 380...415 V and 4 kW at 480 V through 660...690 V — so the same part can be specified across different line voltages without changing the order code. That simplifies BOM management if your plant runs mixed-voltage zones.

At 45 mm wide, 58 mm tall, and 57 mm deep, this contactor fits the standard compact footprint of the TeSys K range. The V1 flame-retardant housing per UL 94 is standard for this class and meets the basic enclosure safety requirement for control panels.

Withstand and coordination

The short-time withstand current (Icw) is rated at 115 A for 1 second on the power circuit, stepping down to 55 A at 1 minute and 25 A for sustained periods over 15 minutes. These numbers matter for selective coordination with upstream protective devices — the contactor can ride through a downstream fault long enough for the breaker or fuse to clear, without welding its own contacts.

Frequently asked questions

What motor power can this contactor handle?

It depends on the supply voltage. At 380...415 V AC it handles 7.5 kW; at 440 V it handles 5.5 kW; at 480 V through 690 V it handles 4 kW; and at 220...230 V it handles 4 kW. All ratings are for AC-3 duty at 50/60 Hz.

What is the physical size of the LC1K16016M7?

Width is 45 mm, height is 58 mm, depth is 57 mm. It mounts on a standard DIN rail.

What is the coil voltage and auxiliary contact configuration?

The coil is rated 220...230 V AC 50/60 Hz. It includes one normally-closed (NC) auxiliary contact.

MPN