Skip to main content
Schneider Electric LC1K16016R7 — Contactors

Schneider LC1K16016R7 TeSys K Contactor, 16 A, 3P, Obsolete

MPNLC1K16016R7
Active

Schneider Electric TeSys K contactor, LC1K16016R7, 3P, AC-3 ≤440 V 16 A, 1 NC auxiliary contact, 440 V AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K16016R7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K16016R7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1
LC1K16016R7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K16016R7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94
LC1K16016R7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K16016R7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current16 A at 20 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

It switches motor loads under AC-3 duty up to 16 A at ≤440 V, and handles resistive loads under AC-1. The coil is 440 V AC. It carries one normally-closed auxiliary contact. Motor power capability spans 4 kW at 480 V AC up to 7.5 kW at 380–415 V AC, covering common three-phase induction motors across European and North American line voltages.

Sourcing reality — obsolete, no official successor

This part is officially obsolete per Schneider Electric's lifecycle status. No direct successor order code is listed.

The 45 mm width occupies one 9 mm module position per pole, typical for this class. Heat dissipation is 1.3 W, low enough that no forced cooling is needed in a standard IP20 control cabinet. The V-0 flame retardance rating per UL 94 means the housing self-extinguishes — a requirement for unventilated enclosures.

Short-circuit and withstand capability

Rated short-time withstand current (Icw) for the power circuit is 115 A for 1 second at 50 °C, tapering to 25 A for 15 minutes or longer. This gives the coordination engineer a curve to size upstream protection — typically a gG fuse or a motor circuit protector set below 115 A.

Frequently asked questions

What replaces the LC1K16016R7?

No official successor order code is published. The TeSys K series has been superseded by the TeSys Deca range, but pin-to-pin compatibility and the 440 V AC coil voltage must be verified against the specific application before substituting.

How do I source this obsolete contactor?

Through the surplus and broker channel. We can source it to order against an RFQ — no shelf stock is held for an obsolete line.

What are the key ratings for this contactor?

Three-pole, AC-3 rated operational current 16 A at ≤440 V, AC-1 rated for resistive loads. Coil voltage 440 V AC. Motor power up to 7.5 kW at 380–415 V AC. One NC auxiliary contact.

MPN
LC1K16016R7