Skip to main content
Schneider Electric LC1K1601G7 — Contactors

Schneider TeSys K LC1K1601G7 Contactor, 3P, 16 A, 120 V AC C

MPNLC1K1601G7
Obsolete

Schneider Electric TeSys K contactor, LC1K1601G7, 3P, AC-3 <= 440 V 16 A, 1 NC auxiliary contact, 120 V AC coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K1601G7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K1601G7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1
LC1K1601G7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K1601G7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94
LC1K1601G7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K1601G7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current16 A at 20 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The Schneider Electric LC1K1601G7 is a TeSys K contactor, 3-pole with 3 NO main contacts and 1 NC auxiliary contact, rated 16 A in AC-3 utilisation category at up to 440 V and 120 V AC coil. It handles motor loads up to 7.5 kW at 380...415 V AC and 4 kW at 480 V AC, 50/60 Hz.

The 16 A rated operational current in AC-3 (motor starting) duty is the figure that governs motor switching — it is not the thermal current. For resistive loads (AC-1) the contactor can handle higher current, but for motor control, 16 A is the hard limit. The motor power ratings span 4 kW at 480 V up to 7.5 kW at 380...415 V; match the line voltage to the appropriate kW row. Short-time withstand current (Icw) is 115 A for 1 s on the power circuit, which gives some headroom for brief overloads or inrush. Heat dissipation is 1.3 W — negligible for panel thermal budgeting. Flame retardance meets UL 94 V1.

Integration notes

The 120 V AC coil is common in North American control circuits; verify coil suppression (RC snubber or varistor) if driving from a PLC output. The 1 NC auxiliary is wired as a mirror contact or status feedback.

Frequently asked questions

What is the closest pin-compatible alternative to the LC1K1601G7?

There is no official pin-compatible successor listed. The TeSys Deca range (LC1D series) is the functional replacement family, but you must verify mounting footprint, coil voltage, and auxiliary contact arrangement against your panel before ordering.

What compliance documentation is available for the LC1K1601G7?

The part carries UL 94 V1 flame retardance rating. For RoHS, REACH, and full IEC/UL certification documents, request them with your RFQ — these are typically available from the manufacturer's archive for obsolete parts.

MPN
LC1K1601G7