Skip to main content
Schneider Electric LC1K16106N7 — Contactors

TeSys K LC1K16106N7 Contactor, 16 A, 400-415 V AC Coil, Obso

MPNLC1K16106N7
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440 V 16 A, 1 NO aux, 400…415 V AC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1K16106N7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LC1K16106N7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1
LC1K16106N7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1K16106N7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94
LC1K16106N7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LC1K16106N7 — Other specifications
ParameterValue
Motor power4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz
Heat dissipation1.3 W
Range of productTeSys K
Device short nameLC1K
Compatibility codeLC1K
Device applicationControl
Pole contact composition3 NO
[Ie] rated operational current16 A at 20 A at 10 MOhm for signalling circuit
[Icw] rated short-time withstand current115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit

Product details

The LC1K16106N7 is a TeSys K three-pole contactor from Schneider Electric, rated 16 A in AC-3 utilisation category at ≤440 V, with a single normally-open auxiliary contact and a 400…415 V AC coil. It is now listed as obsolete.

The AC-3 rating (16 A at ≤440 V) governs motor switching duty — this contactor is sized for a 7.5 kW motor on a 380…415 V supply, or 5.5 kW at 440 V, or 4 kW at 480 V and up to 690 V. The AC-1 rating covers resistive loads at the same current level. The 400…415 V AC coil is specific to that voltage band; it will not pull in reliably on a 480 V control circuit without a dropping resistor or transformer.

Integration notes

The contactor dissipates 1.3 W at rated load — negligible for most enclosures, but worth checking if it sits next to solid-state devices in a sealed cabinet. Flame retardance is V1 per UL 94, which is standard for this class. The 3 NO main poles and 1 NO auxiliary are fixed; no field-convertible contact arrangement.

Frequently asked questions

What replaces LC1K16106N7?

No official successor order code is documented in the available records. A parametric substitute from the same TeSys family would need to match the 16 A AC-3 rating, 3-pole configuration, 1 NO auxiliary, and 400…415 V AC coil voltage.

What are the key ratings for this contactor?

Rated operational current is 16 A in AC-3 category at ≤440 V. Motor power ranges from 4 kW at 220…230 V up to 7.5 kW at 380…415 V. Coil voltage is 400…415 V AC. Short-time withstand current is 115 A for 1 second on the power circuit.

MPN
LC1K16106N7