Skip to main content
Schneider Electric LC1K16107Y7 — Contactors

Schneider LC1K16107Y7 TeSys K Contactor, 3P, 16A AC-3, 690V

MPNLC1K16107Y7
Active

Schneider Electric TeSys K contactor, LC1K16107Y7, 3P, AC-3 ≤440 V 16 A, 1 NO aux., 660...690 V AC coil.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1K16107Y7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys

Ratings & Performance

LC1K16107Y7 — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-1

Contacts & Poles

LC1K16107Y7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1K16107Y7 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94

Mechanical

LC1K16107Y7 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The Schneider Electric LC1K16107Y7 is a TeSys K contactor — a compact 3-pole unit rated 16 A in AC-3 duty at ≤440 V, with a single normally-open auxiliary contact. The coil is wound for 660...690 V AC, so it's built for 690 V line-fed control circuits common in European and export panels. Motor power capability spans 4 kW at 480 V AC up to 7.5 kW at 380...415 V AC, covering a range of voltage standards from 220...230 V through 660...690 V. That's the headline selection number: match your motor's full-load current to the 16 A AC-3 rating, not the kW table, because the kW values assume a specific motor efficiency and power factor. Short-time withstand current (Icw) is 115 A for 1 second on the power circuit — enough to ride through a short-duration fault without welding contacts, provided upstream protection clears within that window. Heat dissipation is 1.3 W, which matters when you stack several contactors in a sealed enclosure.

The 45 mm width is three modular units (each 15 mm), so it occupies three slots on a DIN-rail terminal block assembly. Plan your enclosure fill factor accordingly: at 45 mm wide, you can fit about 6 of these per 300 mm of rail. Flame retardance is V1 per UL 94, meaning the housing self-extinguishes within 30 seconds after a flame source is removed — a standard requirement for control panels in most industrial and commercial occupancies.

Because it's an active, standard part, sourcing is straightforward: quote against an RFQ for your required quantity. No broker or surplus channel needed — this is a current-production item you'd order through normal supply.

Frequently asked questions

What is the closest alternative to the LC1K16107Y7 in the TeSys family?

Within the TeSys K range, the closest alternative would be a contactor with the same 16 A AC-3 rating but a different coil voltage — for example, an LC1K1610 with a 230 V AC coil. The physical footprint, auxiliary contact configuration, and breaking capacity are identical; only the coil voltage changes. No pin-compatible drop-in exists for a different coil voltage without rewiring the control circuit.

What is the depth of the LC1K16107Y7?

The depth is 57 mm, measured from the DIN-rail mounting surface to the front of the contactor body. This does not include the coil terminals or auxiliary contact block if fitted.

What compliance documentation is available for the LC1K16107Y7?

The part carries UL 94 V1 flame retardance certification. Standard Schneider TeSys K contactors are typically UL, CSA, and CE marked, but specific approval markings for this order code should be verified against the nameplate or Schneider's compliance database.

MPN
LC1K16107Y7