Skip to main content
Schneider Electric LC2K09013K7 — Contactors

Schneider Electric LC2K09013K7 TeSys K Reversing Contactor,

MPNLC2K09013K7
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NC, 100 V AC coil, preassembled with reversing power busbar.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC2K09013K7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationMotor control Resistive load
LC2K09013K7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3
LC2K09013K7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K09013K7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K09013K7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The 100 V AC coil means the control circuit must supply 100 V AC nominal; verify your control transformer taps before committing the panel design. The 3-pole NO power circuit handles three-phase reversal, and the 1 NC auxiliary contact provides a positive-break feedback path for the reversing interlock.

IP20 finger-safe protection (VDE 0106) means it is suited for enclosed panels where personnel access is restricted. The preassembled reversing busbar saves wiring time and reduces the chance of phase-crossing errors during commissioning.

Rated for operation from -25 to 50 °C and storage from -50 to 80 °C, with no derating needed up to 2000 m altitude. Flame retardance meets UL 94 V1 and NF F 16-101/102, and the protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance. Shock and vibration ratings are specified per IEC 60068-2-27 and IEC 60068-2-6 — the contactor holds closed through 10 Gn on X-axis and 15 Gn on Y/Z axes, which is relevant for rail or mobile equipment installations.

Frequently asked questions

What replaces the LC2K09013K7?

No official replacement order code is listed by Schneider Electric. For a BOM that requires this exact reversing contactor, the only path is to source the LC2K09013K7 itself through surplus channels. A parametric substitute from the TeSys K or TeSys D range would require verifying coil voltage, pole configuration, and mounting footprint.

What are the key ratings of the LC2K09013K7?

It is a 3-pole reversing contactor rated 9 A in AC-3 utilisation category at up to 440 V, with a 100 V AC coil. It includes 1 NC auxiliary contact and is preassembled with a reversing power busbar.

What compliance documentation is available for the LC2K09013K7?

The contactor carries flame retardance ratings per UL 94 V1 and NF F 16-101/102, protective treatment per IEC 60068 and DIN 50016, and shock/vibration compliance per IEC 60068-2-27 and IEC 60068-2-6. IP20 protection is per VDE 0106.

MPN