Skip to main content
Schneider Electric LC2K09013L7 — Contactors

Schneider LC2K09013L7 TeSys K Reversing Contactor, 9 A AC-3,

MPNLC2K09013L7
Active

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NC, 200...208 VAC coil, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC2K09013L7 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LC2K09013L7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3 AC-4 AC-1
LC2K09013L7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC2K09013L7 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LC2K09013L7 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The 200-208 VAC 50/60 Hz coil matches common North American control voltages. IP20 finger-safe terminals (per VDE 0106) keep panel wiring straightforward.

The AC-3 9 A rating at 440 V is the motor-switching current — this contactor starts and stops a 3-phase induction motor drawing up to 9 A during running, and it handles the higher inrush on make. AC-4 covers plugging and inching duty at the same current level. AC-1 resistive rating is higher but rarely the limiting factor for motor control. Operate without derating up to 2000 m altitude; above that, consult the thermal curve. The IP20 enclosure means it's for panel mounting only, not washdown areas.

Frequently asked questions

What are the key ratings of the LC2K09013L7?

It is a 3-pole reversing contactor rated AC-3 at 9 A up to 440 V, with a 200-208 VAC 50/60 Hz coil. It includes one NC auxiliary contact and is preassembled with the reversing power busbar.

What is the depth of the LC2K09013L7?

The depth is 57 mm.

What is the TeSys range for this contactor?

It belongs to the TeSys K product range, which is a compact contactor series from Schneider Electric for motor control up to 9 A AC-3.

MPN
LC2K09013L7