The Schneider Electric LC2K1601FE7 is a TeSys K reversing contactor, 3P, rated AC-3 <=440 V 16 A, with a 115 V AC coil and one NC auxiliary contact. Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, so the 16 A AC-3 mark is the motor-switching limit — not the full voltage ceiling. Utilisation categories AC-3 and AC-4 cover both normal starting and plugging/inching duty on squirrel-cage motors. IP20 finger-safe terminals (VDE 0106) suit enclosed panel mounting; the 57 x 90 x 58 mm footprint fits standard DIN-rail layouts alongside other TeSys K components.
Schneider Electric LC2K1601FE7 TeSys K Reversing Contactor,
MPNLC2K1601FE7
Obsolete
Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 115 V AC coil, IP20, 57 x 90 x 58 mm.
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Reversing contactor |
| Series / range | TeSys |
| Application | Motor control |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-3 AC-4 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to VDE 0106 |
| Operating altitude | 2000 m without derating |
| Mechanical robustness | Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TC conforming to IEC 60068 TC conforming to DIN 50016 |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Width | 90 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings of the LC2K1601FE7?
It is a 3-pole reversing contactor rated AC-3 <=440 V 16 A, with a 115 V AC coil and one NC auxiliary contact. The power circuit is rated 690 V AC 50/60 Hz, and it is IP20 finger-safe.
What is the depth of the LC2K1601FE7?
The depth is 57 mm, with a width of 90 mm and height of 58 mm.
What compliance documentation is available for this part?
The contactor carries flame retardance V1 per UL 94, and conforms to NF F 16-101 and NF F 16-102. It also meets IEC 60068 for shock/vibration and IP20 per VDE 0106.
MPN
LC2K1601FE7