Skip to main content
Schneider Electric LC3D180AE7 — Contactors

Schneider TeSys LC3D180AE7 Star Delta Starter, 18 A, 48 V AC

MPNLC3D180AE7
Obsolete

Schneider Electric TeSys D, star delta starter, 3 x 3P (3 NO), 18 A, 48 V AC coil, IP20 front face.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC3D180AE7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3D180AE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-3
LC3D180AE7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3D180AE7 — Environmental
ParameterValue
IP degree of protectionIP20 front face conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Vibrations contactor closed: 4 Gn, 5...300 Hz Shocks contactor open: 10 Gn for 11 ms Shocks contactor closed: 15 Gn for 11 ms
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Product details

The Schneider LC3D180AE7 is a TeSys D star delta starter, pre-wired with three power poles (3 x 3P, all NO) rated for 18 A in AC-3 motor duty. The 48 V AC coil matches control circuits common in older panel designs or where a separate control transformer steps down to 48 V. It is built for motor starting applications where reduced inrush current is needed — star-delta transition limits the start surge to about one-third of direct-on-line, which is easier on the supply and the driven load.

If you need a current-production star delta starter in the TeSys D family, the closest functional match would be a newer frame with similar pole configuration and coil voltage — but pin-to-pin compatibility is not guaranteed without checking the physical layout and wiring diagram.

The 18 A AC-3 rating is the motor-switching current — it handles a 3-phase induction motor up to roughly 7.5 kW at 400 V (standard rule of thumb: 18 A AC-3 ≈ 7.5 kW). The 48 V AC coil means the control voltage is lower than the common 110/230 V AC, so verify your control transformer taps or PLC relay outputs before wiring. Fire resistance to 850 °C (IEC 60695-2-1) and V-0 flame retardance (UL 94) mean the housing will not propagate a flame in a fault condition — important for panel builders who need to pass a cabinet-level fire test.

Deployment context

As a pre-wired star delta starter, it mounts directly on DIN rail or a backplate inside a motor control centre. The 3 x 3P configuration means it has three normally-open power poles per phase — nine poles total — which handle the star and delta contactor duties plus the line contactor in a single package. Storage temperature range of -60 to 80 °C covers extreme shipping and warehouse conditions.

Frequently asked questions

What replaces the LC3D180AE7?

There is no official successor order code listed in the lifecycle record. A current-production TeSys D star delta starter with similar ratings (18 A AC-3, 48 V AC coil) would be the closest functional match, but verify physical compatibility before ordering.

What are the key ratings of the LC3D180AE7?

It is a star delta starter rated 18 A in AC-3 motor duty, with a 48 V AC coil, 3 x 3P (9 NO power poles), IP20 front face, pollution degree 3, and fire resistance to 850 °C.

What compliance documentation is available for the LC3D180AE7?

The part carries IEC 60947-1 Annex Q category D climatic withstand, IEC 60068-2-30 TH protective treatment, and UL 94 V-0 flame retardance. Fire resistance conforms to IEC 60695-2-1 at 850 °C.

MPN
LC3D180AE7