Rated 80 A in AC-3 utilisation category, it handles motor switching up to that current during the transition from star to delta connection. The 24 V AC coil matches standard control voltages found across industrial panels.
This part is marked obsolete by the manufacturer. Sourcing is via surplus or broker channel against an RFQ.
If your motor full-load current is under 80 A at the rated operational voltage, this starter is sized correctly for the star-delta transition. Operating temperature range spans -40 to 140 °F (-40 to 60 °C), with derating required above 140 °F up to 158 °F (70 °C). Storage tolerance is wider at -76 to 176 °F (-60 to 80 °C). The TH protective treatment per IEC 60068-2-30 means it withstands damp heat cycling — relevant if the enclosure sees condensation or humidity swings. Flame retardance is V1 per UL 94, and fire resistance meets 1562 °F (850 °C) per IEC 60695-2-1 — both indicate the plastic housing resists ignition and does not propagate flame, which matters for panel certification and safety reviews.