Schneider Electric LC3F150M7 — Contactors

Schneider TeSys F LC3F150M7 Star Delta Starter, 150 A AC-3

MPNLC3F150M7
Obsolete

Schneider Electric TeSys F series, LC3F150M7 star delta starter, 150 A rated operational current (AC-3), 230 V AC 50/60 Hz control circuit, pre-wired assembly.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC3F150M7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F150M7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F150M7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F150M7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) without derating
Mechanical robustnessVibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed6 Gn, 5...300 Hz Shocks contactor open9 Gn for 11 ms Shocks contactor closed15 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F150M7 — Approvals
ParameterValue
StandardsIEC 60947-1 EN 60947-1 EN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1

Product details

The LC3F150M7 is a pre-wired star delta starter from the Schneider TeSys F range, built for three-phase induction motor starting where reduced inrush current is needed. The motor power it can manage depends on the supply voltage: 69 kW at 220/230 V AC, 130 kW at 380/400 V AC, and 173 kW at both 415 V and 440 V AC, all at 50/60 Hz. The control circuit is fixed at 230 V AC 50/60 Hz, with a coil that holds in at 45 VA (50 Hz) and drops out between 0.35 and 0.55 Uc.

AC-3 covers starting and plugging of squirrel-cage motors, so the 150 A is the continuous current the main poles carry during running, not the starting surge.

Where this starter is used

This is a plate-mounted, pre-wired assembly, not a DIN-rail component. The mounting support is a plate, and the power connections are via M8 bolted lugs or busbars (25 x 3 mm cross-section). The control circuit uses screw clamp terminals accepting 1 to 4 mm² flexible or solid wire. The IP20 front face protection with shrouds means it is safe for finger contact inside an enclosure but not for washdown environments. It is sized for motor control centres or dedicated starter panels where the star-delta transition timing is set by the 20-second starting time and the 23 to 35 ms closing / 5 to 15 ms opening operating times.

The LC3F150M7 is designed and certified to IEC 60947-1, EN 60947-1, EN 60947-4-1, IEC 60947-4-1, and JIS C8201-4-1. The rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. The protective treatment is TH (tropicalised), which means it is suitable for humid or corrosive atmospheres without additional conformal coating.

Frequently asked questions

What is the closest alternative to the LC3F150M7?

Within the TeSys F range, the LC3F150M7 is a specific pre-wired star delta starter with a 150 A AC-3 rating and 230 V AC control. A direct alternative would be a functionally equivalent star delta starter from the same range with the same current and voltage ratings. There is no pin-compatible drop-in replacement from a different series that carries the same pre-wired assembly and control voltage without requalifying the panel layout.

What compliance documentation is available for the LC3F150M7?

The LC3F150M7 is certified to IEC 60947-1, EN 60947-1, EN 60947-4-1, IEC 60947-4-1, and JIS C8201-4-1. The rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Standard Schneider documentation includes the datasheet, installation manual, and declaration of conformity for these standards.