Schneider Electric LC3F185FE7 — Contactors

Schneider Electric LC3F185FE7 TeSys F Star Delta Starter, 18

MPNLC3F185FE7
Obsolete

Schneider Electric TeSys F LC3F185FE7, pre-wired star delta starter, 3 x 3P, 185 A AC-3 at ≤440 V, 115 V AC 50/60 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC3F185FE7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F185FE7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F185FE7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F185FE7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F185FE7 — Approvals
ParameterValue
StandardsJIS C8201-4-1 EN 60947-1 IEC 60947-1 IEC 60947-4-1 EN 60947-4-1
LC3F185FE7 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

The Schneider Electric LC3F185FE7 is a pre-wired star delta starter from the TeSys F range, designed for motor control applications. It integrates three contactors — KM1 star, KM2 line, and KM3 delta — with the interlocking logic already wired, so it lands as a single unit ready for plate mounting rather than a pile of loose contactors and timers. Rated 185 A in AC-3 utilisation category at ≤440 V, it handles motor starts up to that current without welding the main poles. The AC-3 rating means it is tested for switching squirrel-cage motors — making and breaking stalled-rotor currents during start and running at full load during stop. That 185 A figure governs the motor size it can handle; at 380/400 V it drives a 160 kW motor, at 440 V it steps up to 185 kW. The coil is 115 V AC 50/60 Hz, with an operational range of 0.85 to 1.1 Uc for pick-up and a drop-out band of 0.35 to 0.55 Uc. Inrush power hits 805 VA at 50 Hz and 970 VA at 60 Hz, so the control transformer must be sized for that peak, not just the sealed hold.

The auxiliary contact composition is already set for the star-delta sequence: 1 NC + 1 NO on KM1, 2 NC + 1 NO on KM2, and 1 NC + 2 NO on KM3. That covers the interlocking and signalling without needing add-on blocks. The power pole contacts are 3 x 3 NO — three poles per contactor, all normally open. Mounting is plate-mount, not DIN rail, which is typical for this frame size. The footprint is 525 mm wide by 235 mm deep by 110 mm tall — plan panel space accordingly. Power connections accept lugs or ring terminals up to 150 mm², or a busbar cross-section of 25 x 3 mm, with an M8 bolt. Control wiring uses screw-clamp terminals accepting 1 to 4 mm² flexible or solid. Heat dissipation runs 18 to 24 W in continuous duty. That is low enough for most enclosed panels, but if the starter is cycling near its maximum operating rate of 2400 cycles per hour at 55 °C, the internal temperature rise needs a check against the enclosure's thermal budget.

The LC3F185FE7 carries compliance with IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. The front face with shrouds achieves IP2X per IEC 60529 and VDE 0106. Protective treatment is TH for tropical environments.

Sourcing and procurement takeaway

For a BOM line calling out LC3F185FE7, the fit is confirmed by the 185 A AC-3 rating, 115 V AC coil, and the pre-wired star-delta configuration. The associated fuse recommendation is 315 A gG or 200 A aM at ≤440 V. Rated breaking capacity is 1480 A, and rated making capacity is 1850 A, both per IEC 60947-4-1. The part is specified into the design as a single order code — no separate contactor or timer selection needed.

Frequently asked questions

What are the key ratings for the LC3F185FE7?

The LC3F185FE7 is rated 185 A in AC-3 at ≤440 V, with a 115 V AC 50/60 Hz coil. It handles motor loads up to 160 kW at 380/400 V and 185 kW at 440 V. Mechanical durability is 10 million cycles.

What is the mounting and connection style for this starter?

It is plate-mounted with a footprint of 525 x 235 x 110 mm. Power connections accept lugs or ring terminals up to 150 mm², or a 25 x 3 mm busbar with M8 bolts. Control wiring uses screw-clamp terminals for 1 to 4 mm² conductors.

What standards does the LC3F185FE7 comply with?

It complies with IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Front-face protection is IP2X with shrouds.

MPN
LC3F185FE7