Schneider Electric LC3F185FE7A64 — Contactors

Schneider Electric LC3F185FE7A64 TeSys F Star Delta Starter,

MPNLC3F185FE7A64
Obsolete

Schneider Electric TeSys F LC3F185FE7A64, star delta starter, 185 A AC-3, 160 kW at 400 V, 115 V AC 50/60 Hz control, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC3F185FE7A64 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F185FE7A64 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F185FE7A64 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F185FE7A64 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F185FE7A64 — Approvals
ParameterValue
StandardsEN 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 IEC 60947-1
LC3F185FE7A64 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

It integrates three contactors — star, line, and delta — with mechanical interlocking and the auxiliary contacts already wired, so it lands as a single assembly for panel integration. Rated 185 A in AC-3 duty at ≤ 440 V, it switches motor loads up to 160 kW on a 400 V supply. The 115 V AC 50/60 Hz control coil pulls 805 VA inrush at 50 Hz and holds within 0.85 to 1.1 Uc, with dropout between 0.35 and 0.55 Uc.

The AC-3 rating (185 A) governs motor switching — inrush during start and break during stop. The associated fuse guide of 315 A gG or 200 A aM at ≤ 440 V tells you what upstream protection keeps the starter within its short-circuit rating. Breaking capacity is listed at 1480 A per IEC 60947-4-1; making capacity at 1850 A. The starter mounts to a plate (not DIN rail) and measures 525 mm wide × 110 mm high × 235 mm deep — plan for a backplate that clears the M8 power-bolt connections and the lug/ring terminals accepting up to 150 mm² cable. Vibration resistance is 5 Gn closed, 2 Gn open; shock resistance 15 Gn closed for 11 ms. Altitude derating starts above 3000 m.

Star delta starters like this one are standard for reducing inrush current on three-phase induction motors during start-up — common on pumps, compressors, conveyors, and fans where the driven load doesn't need full torque at zero speed. The LC3F185FE7A64 fits motor control centres and panel builds that spec a pre-wired, tested assembly rather than wiring three individual contactors.

Frequently asked questions

What are the key ratings for this star delta starter?

Rated operational current is 185 A in AC-3 at ≤ 440 V, motor power is 160 kW at 400 V, control voltage is 115 V AC 50/60 Hz, and it mounts to a plate.

What compliance standards does it meet?

It complies with IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Front-face IP2X protection with shrouds per IEC 60529 and VDE 0106.