Skip to main content
Schneider Electric LC3F185P7 — Contactors

Schneider LC3F185P7 TeSys F Star Delta Starter, 185 A AC-3,

MPNLC3F185P7
Obsolete

Schneider Electric TeSys F star delta starter, LC3F185P7, 185 A AC-3 rated operational current, 160 kW at 400 V, pre-wired assembly.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC3F185P7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F185P7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F185P7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F185P7 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F185P7 — Approvals
ParameterValue
StandardsIEC 60947-4-1 EN 60947-1 IEC 60947-1 JIS C8201-4-1 EN 60947-4-1
LC3F185P7 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

Rated 185 A in AC-3 duty (switching squirrel-cage motors) at up to 440 V, it handles motor loads up to 160 kW at 380/400 V and 185 kW at 440 V. The control circuit is 230 V AC 50/60 Hz, with an inrush draw of 805 VA at 50 Hz and 970 VA at 60 Hz.

The 185 A AC-3 rating is the key selection number — it tells you the continuous current the starter can handle while switching motor loads under full load. AC-3 covers starting and plugging of cage motors, which is the standard duty for a star-delta starter. The motor power table gives you the matching kW at common line voltages: 160 kW at 400 V, 185 kW at 440 V, and 90 kW at 230 V. Match your motor's nameplate to these figures — the starter is sized for the motor, not the other way around. The pre-wired assembly includes three contactors with specific auxiliary contact configurations: 1 NC + 1 NO on the star contactor, 2 NC + 1 NO on the line contactor, and 1 NC + 2 NO on the delta contactor. This is the standard complement for a star-delta sequence and saves you wiring time. Rated insulation voltage is 1000 V per IEC 60947-4-1.

This is a plate-mount assembly, not a DIN-rail snap-on. The footprint is 525 mm wide by 235 mm deep by 110 mm tall, so plan your enclosure backplate space accordingly. Power connections use M8 bolts with lugs or busbars up to 150 mm²; control wiring is screw-clamp terminals. Rated for operation up to 3000 m altitude without derating, so it works at most plant elevations without a second thought.

Compliant with IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1.

Frequently asked questions

What motor power can the LC3F185P7 handle?

It handles 160 kW at 380/400 V, 185 kW at 440 V, and 90 kW at 220/230 V, all at 50/60 Hz.

What are the physical dimensions of the LC3F185P7?

Width 525 mm, depth 235 mm, height 110 mm. It is a plate-mount assembly.

What standards does the LC3F185P7 comply with?

It complies with IEC 60947-4-1, EN 60947-1, IEC 60947-1, JIS C8201-4-1, and EN 60947-4-1.

MPN