Schneider Electric LC3F185P7A64 — Contactors

Schneider TeSys F LC3F185P7A64 Star Delta Starter, 185 A AC-

MPNLC3F185P7A64
Obsolete

Schneider Electric TeSys F LC3F185P7A64, pre-wired star delta starter, 3 x 3P, 185 A AC-3, 230 V AC 50/60 Hz coil, plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC3F185P7A64 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control
LC3F185P7A64 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3
LC3F185P7A64 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P
LC3F185P7A64 — Environmental
ParameterValue
IP degree of protectionIP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 7 Gn for 11 ms
Protective treatment / pollution degreeTH
LC3F185P7A64 — Approvals
ParameterValue
StandardsJIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 EN 60947-1 IEC 60947-1
LC3F185P7A64 — Mechanical
ParameterValue
Width525 mm
Height110 mm
Depth235 mm

Product details

The Schneider Electric TeSys F LC3F185P7A64 is a pre-wired star delta starter, purpose-built for motor control in the AC-3 utilisation category. It's rated for 185 A operational current at ≤440 V AC, which translates to 160 kW at 380/400 V AC and 185 kW at 440 V AC. The 230 V AC 50/60 Hz control circuit pulls 805 VA inrush at 50 Hz. This is a three-pole, three-contactor assembly with mechanical interlocking, so the star and delta contactors cannot close simultaneously — a hard requirement for preventing phase-to-phase shorts during transition.

The 185 A AC-3 rating is the motor-switching current, not a resistive-heat rating. AC-3 means it handles inrush during starting and breaks the motor at full load — the worst case for contact wear. The rated making capacity of 1850 A and breaking capacity of 1480 A (both per IEC 60947-4-1) tell you the contacts can close into and interrupt a stalled-rotor fault without welding or failing to clear. The mechanical durability of 10 Mcycles means the contactor block itself will outlast most applications; the electrical life will be lower and depends on switching frequency and load. The auxiliary contact complement is generous: 1 NC + 1 NO on the star contactor, 2 NC + 1 NO on the line contactor, and 1 NC + 2 NO on the delta contactor. That's enough for status feedback, interlocking, and a run signal without adding an external aux block. The control circuit voltage limits are 0.85...1.1 Uc for pick-up and 0.35...0.55 Uc for drop-out, so the coil holds in reliably down to about 195 V AC and drops out below about 126 V AC. The power circuit accepts lugs, ring terminals up to 150 mm², or busbars (25 x 3 mm cross-section) with M8 bolted connections. Control wiring uses screw clamp terminals accepting 1...4 mm² flexible or solid. Tightening torque is 1.2 N·m on the control circuit and 18 N·m on the power circuit — the power lugs need a torque wrench, not a screwdriver.

This is a plate-mount assembly, not DIN-rail. The footprint is 525 mm wide × 110 mm high × 235 mm deep. It's pre-wired internally, so the only field connections are the incoming line, motor leads, and control wires. The TH protective treatment indicates it's tropicalized for humidity and condensation.

The starter is designed and tested to IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1 for contactors and starters. The rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. The associated fuse ratings are 315 A gG or 200 A aM at ≤440 V — use these for short-circuit coordination.

Frequently asked questions

What are the key ratings for this star delta starter?

The LC3F185P7A64 is rated 185 A AC-3 at ≤440 V, with a 230 V AC 50/60 Hz control coil. It handles motors up to 160 kW at 400 V and 185 kW at 440 V. The rated making capacity is 1850 A and breaking capacity is 1480 A per IEC 60947-4-1.

What is the mounting and connection method?

It is a plate-mount assembly, not DIN-rail. Power connections accept lugs, ring terminals up to 150 mm², or busbars with M8 bolts. Control wiring uses screw clamp terminals for 1...4 mm² conductors.

What standards does this starter comply with?

It complies with IEC 60947-4-1, EN 60947-4-1, and JIS C8201-4-1. The rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C.