Schneider TeSys F LC3F265P7 Star Delta Starter, 265 A AC-3

MPNLC3F265P7
Obsolete

Schneider Electric TeSys F series, LC3F265P7 star delta starter, 265 A rated operational current (AC-3), 230 V AC 50/60 Hz control circuit, pre-wired assembly.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC3F265P7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC3F265P7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3

Contacts & Poles

LC3F265P7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P

Environmental

LC3F265P7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms
Protective treatment / pollution degreeTH

Approvals

LC3F265P7 — Approvals
ParameterValue
StandardsEN 60947-4-1 JIS C8201-4-1 IEC 60947-1 IEC 60947-4-1 EN 60947-1

Mechanical

LC3F265P7 — Mechanical
ParameterValue
Width625 mm
Height110 mm
Depth266 mm

Product details

The Schneider Electric TeSys F LC3F265P7 is a pre-wired star delta starter designed for motor control applications. It's a 3-pole assembly rated for 265 A operational current in AC-3 utilisation category, meaning it handles the high inrush of squirrel-cage motors during start-up and transitions to delta run. Motor power ratings span 110 kW at 220/230 V AC up to 250 kW at 440 V AC, 50/60 Hz. The control circuit runs on 230 V AC 50/60 Hz, with an operational voltage range of 0.85 to 1.1 Uc and dropout at 0.35 to 0.55 Uc. Coil inrush is 650 VA at 40-400 Hz, cos φ 0.9 at 20 °C. Steady-state heat dissipation is 8 W. Auxiliary contact configuration is built in: 1 NC + 1 NO on the star contactor (KM1), 2 NC + 1 NO on the line contactor (KM2), and 1 NC + 2 NO on the delta contactor (KM3). This covers the interlocking and signalling needs of a standard star-delta start sequence without adding external aux blocks.

AC-3 means it's rated for starting and switching off squirrel-cage motors during running — the contactor must make and break the motor's locked-rotor current. The associated fuse recommendation is 400 A gG or 315 A aM at ≤ 440 V, which sets the short-circuit protection level for the branch circuit. Rated making capacity is 2650 A and breaking capacity is 2120 A, both per IEC 60947-4-1. These numbers tell you the contactor can close onto and interrupt fault currents at those levels — important for coordination with upstream protection. The rated insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 Group C. For a star-delta starter that cycles on every motor start, this gives a solid service life in high-duty applications like conveyors or compressors.

Mounting is plate-mount, not DIN rail — this is a heavy assembly (625 mm wide, 266 mm deep, 110 mm high) that bolts to a backplate in the enclosure. Power connections are via bolted busbars (M10 bolts, 32 x 4 mm busbar cross-section) or ring terminals up to 240 mm². Control wiring uses screw clamp terminals accepting 1 to 4 mm² flexible or solid cable. The pre-wired design means the internal star-delta wiring between contactors is factory-completed. You land the incoming line, motor leads, and control wires. Torque specs: 35 N·m on power circuit connections, 1.2 N·m on control circuit terminals.

Standards compliance covers IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Protective treatment is TH (tropicalized) for humid environments.

Frequently asked questions

What are the key ratings for this star delta starter?

Rated operational current is 265 A in AC-3 at ≤ 440 V. Motor power ranges from 110 kW at 220/230 V to 250 kW at 440 V AC. Control voltage is 230 V AC 50/60 Hz. Mechanical durability is 10 million cycles.

What compliance standards does the LC3F265P7 meet?

It complies with IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 Group C.

What are the physical dimensions and mounting requirements?

Width 625 mm, depth 266 mm, height 110 mm. Plate-mount only — not DIN rail. Power connections use M10 bolts with busbar cross-section 32 x 4 mm or ring terminals up to 240 mm².

MPN
LC3F265P7