Skip to main content
Schneider Electric LC3F265V7A64 — Contactors

Schneider TeSys F LC3F265V7A64 Star Delta Starter, 265 A AC-

MPNLC3F265V7A64
Obsolete

Schneider Electric TeSys F LC3F265V7A64 pre-wired star delta starter, 3 x 3P, 265 A AC-3, 400 V AC 50/60 Hz control, plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC3F265V7A64 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC3F265V7A64 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3

Contacts & Poles

LC3F265V7A64 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P

Environmental

LC3F265V7A64 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms
Protective treatment / pollution degreeTH

Approvals

LC3F265V7A64 — Approvals
ParameterValue
StandardsEN 60947-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-4-1 IEC 60947-1

Mechanical

LC3F265V7A64 — Mechanical
ParameterValue
Width625 mm
Height110 mm
Depth266 mm

Product details

It's rated at 265 A operational current at ≤440 V AC for the power circuit, which translates to 220 kW at 380/400 V AC 50/60 Hz or 250 kW at 440 V AC 50/60 Hz. That's a serious motor starter for a 250 kW pump or compressor on a 440 V line. The control circuit runs on 400 V AC 50/60 Hz, with a pickup range of 0.85 to 1.1 Uc and dropout between 0.35 and 0.55 Uc. Inrush power is 650 VA at 40–400 Hz, cos φ 0.9 at 20 °C. That 400 V coil voltage is common in European industrial panels — it saves a control transformer if your panel already runs 400 V line-to-line.

AC-3 means making and breaking a motor at full load, which is harder on contacts than resistive switching. The associated fuse recommendation is 400 A gG or 315 A aM at ≤440 V, so plan your upstream protection accordingly. Rated breaking capacity is 2120 A and making capacity is 2650 A, both per IEC 60947-4-1 — that's the fault-clearing ability if a motor stalls or shorts. The auxiliary contact complement is already built in: 1 NC + 1 NO on the KM1 star contactor, 2 NC + 1 NO on the KM2 line contactor, and 1 NC + 2 NO on the KM3 delta contactor. That covers the standard star-delta interlocking and status feedback without adding auxiliary blocks. Mechanical interlocking between contactors is included — no external linkage needed.

This is a plate-mount unit — not DIN-rail. Dimensions are 625 mm wide × 110 mm high × 266 mm deep, so it needs a backplate or sub-panel, not a 35 mm rail. Power connections are bolted, with bar cross-section 32 × 4 mm or ring terminals up to 240 mm². Control wiring uses screw clamp terminals accepting 1 to 4 mm² flexible or solid. Tightening torque is 35 N·m on the power circuit and 1.2 N·m on control — a torque wrench is expected on the power lugs. IP20 front face with shrouds per IEC 60529 and VDE 0106 — that's touch-safe from the front but not sealed against dust ingress. Not for washdown environments.

Frequently asked questions

What are the key ratings I need to check for fit?

The headline rating is 265 A at ≤440 V AC in AC-3 duty, which handles motors up to 220 kW at 400 V or 250 kW at 440 V. Control voltage is 400 V AC 50/60 Hz. Mechanical durability is 10 million cycles.

What standards does this star delta starter comply with?

It complies with IEC 60947-4-1, IEC 60947-1, EN 60947-4-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C.

What mounting does this require?

Plate mount only — not DIN-rail compatible. Dimensions are 625 mm wide × 110 mm high × 266 mm deep. Power connections are bolted with M10 hardware.

MPN
LC3F265V7A64