Schneider TeSys F LC3F330E7A64 Star-Delta Starter, 330 A AC-

MPNLC3F330E7A64
Obsolete

Schneider Electric TeSys F LC3F330E7A64, pre-wired star-delta starter, 330 A AC-3, 48 VAC 50/60 Hz coil, plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC3F330E7A64 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC3F330E7A64 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3

Contacts & Poles

LC3F330E7A64 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P

Environmental

LC3F330E7A64 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms
Protective treatment / pollution degreeTH

Approvals

LC3F330E7A64 — Approvals
ParameterValue
StandardsJIS C8201-4-1 IEC 60947-1 EN 60947-1 IEC 60947-4-1 EN 60947-4-1

Mechanical

LC3F330E7A64 — Mechanical
ParameterValue
Width725 mm
Height110 mm
Depth276 mm

Product details

The Schneider Electric TeSys F LC3F330E7A64 is a pre-wired star-delta starter, purpose-built for reducing inrush current during three-phase motor starting. It integrates three contactors (line, star, delta) with a mechanical interlock, pre-wired internally, so the panel builder gets a single unit to mount and connect rather than assembling three separate contactors and the interlock wiring. Rated at 330 A in AC-3 duty (motor switching) at ≤ 440 V, it handles motor loads up to 315 kW at 440 V AC, 280 kW at 380/400 V, or 160 kW at 220/230 V. The 48 V AC 50/60 Hz control coil is the standard for many industrial control circuits, and the pickup/drop-out limits (0.85...1.1 Uc operational, 0.35...0.55 Uc drop-out) mean it holds in reliably on a sagging line but drops out cleanly when the control signal is removed. The star-delta transition is timed by the built-in starting timer set to 30 s, with contactor operating times of 40...65 ms closing and 100...170 ms opening. This sequence is critical: the star contactor closes first, then after the timer delay, the star opens and the delta closes, all mechanically interlocked to prevent a phase-to-phase short.

The 330 A rated operational current (Ie) in AC-3 is the figure that governs motor duty — it is not a general-purpose resistive rating. AC-3 means switching of squirrel-cage motors: making during starting (up to 6× inrush) and breaking during running. The associated fuse ratings (500 A gG or 400 A aM at ≤ 440 V) provide the short-circuit protection the starter needs to coordinate with upstream devices. The insulation voltage rating is 1000 V (IEC 60947-4-1) or 1500 V (VDE 0110 Group C), so it is suitable for 690 V systems common in heavy industrial installations, not just 400 V. The operating altitude of 3000 m without derating covers most installations outside high-altitude mining or ski-lift applications. Mechanical durability of 10 Mcycles and a maximum operating rate of 2400 cycles/hour at 55 °C mean this starter is built for high-duty-cycle applications like conveyors, compressors, and pumps that cycle frequently. The TH protective treatment indicates it is tropicalized for humid or corrosive environments.

Mounting is plate-mount (not DIN rail), sized at 725 mm wide × 110 mm high × 276 mm deep. Power connections are via M10 bolted lugs accepting up to 240 mm² cable or 30 × 5 mm busbar. Control circuit terminals are screw-clamp, accepting 1...4 mm² flexible or solid wire. Tightening torque is 35 N·m on the power circuit and 1.2 N·m on the control circuit — a torque wrench is expected for the power connections. The pre-wired internal contactor assembly includes auxiliary contacts: 1 NC + 1 NO on the star contactor, 2 NC + 1 NO on the line contactor, and 1 NC + 2 NO on the delta contactor — enough for status feedback and interlocking without adding auxiliary blocks.

Frequently asked questions

What are the key ratings for this star-delta starter?

The LC3F330E7A64 is rated 330 A in AC-3 duty at ≤ 440 V, with a 48 VAC 50/60 Hz control coil. It handles motor power up to 315 kW at 440 V, 280 kW at 380/400 V, or 160 kW at 220/230 V. The built-in starting timer is set to 30 seconds.

What standards does this part comply with?

It complies with IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. The insulation voltage rating is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 Group C.