Schneider Electric LC3F400M7 — Contactors

Schneider Electric LC3F400M7 TeSys F Star Delta Starter, 185

MPNLC3F400M7
Obsolete

Schneider Electric TeSys F LC3F400M7, pre-wired star delta starter, 3 x 3P, AC-3, 185 kW at 220/230 V AC, 315 kW at 380/400 V AC, 355 kW at 415 V AC, 375 kW at 440 V AC, 220/230 V AC 50/60 Hz coil.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC3F400M7 — Identification
ParameterValue
Product / component typeStar delta starter
Series / rangeTeSys
ApplicationMotor control

Ratings & Performance

LC3F400M7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit <= 1000 V AC 16 Hz 2/3...200 Hz
Utilisation categoryAC-3

Contacts & Poles

LC3F400M7 — Contacts & Poles
ParameterValue
Pole configuration3 x 3P

Environmental

LC3F400M7 — Environmental
ParameterValue
IP degree of protectionIP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106
Operating altitude9842.52 ft (3000 m) with derating factor
Mechanical robustnessShocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 11 ms Vibrations contactor open1.5 Gn, 5...300 Hz
Protective treatment / pollution degreeTH

Approvals

LC3F400M7 — Approvals
ParameterValue
StandardsEN 60947-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1

Mechanical

LC3F400M7 — Mechanical
ParameterValue
Width28.5 in (725 mm)
Height7.09 in (180 mm)
Depth10.9 in (276 mm)

Product details

The Schneider Electric LC3F400M7 is a pre-wired TeSys F star delta starter, designed for motor control in AC-3 utilisation category. Motor power ratings are voltage-dependent: 185 kW at 220/230 V AC, 315 kW at 380/400 V AC, 355 kW at 415 V AC, and 375 kW at 440 V AC, all at 50/60 Hz. The AC-3 category means it is rated for starting squirrel-cage motors and switching them off during running — the standard duty for a motor starter.

Rated making capacity is 4000 A and breaking capacity is 3200 A, both conforming to IEC 60947-4-1. The associated fuse rating is 500 A gG or 400 A aM at up to 440 V. For a star delta starter, this is a high-duty rating — suitable for frequent starting applications like conveyors or pumps that cycle often. The control circuit voltage limits are 0.85...1.1 Uc for operational pick-up and 0.35...0.55 Uc for drop-out, at 40...400 Hz and up to 55 °C. This means the coil holds in reliably down to about 187 V and drops out below about 127 V — a wide tolerance that handles brownout conditions on site. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 Group C. This gives headroom for 690 V systems common in heavy industrial installations.

Physical integration and mounting

Mounting is plate-mount — no DIN rail. Dimensions are 28.5 in (725 mm) wide, 10.9 in (276 mm) deep, and 7.09 in (180 mm) high. This is a large assembly; plan for a dedicated sub-panel or backplate in the enclosure. The power circuit uses bolted connections with M10 bolts, accepting ring terminals up to 150 mm² or busbars 30 x 5 mm. Install in a clean, dry enclosure. The protective treatment is TH — tropicalized for humidity and fungus resistance. Power pole contact composition is 3 x 3 NO — nine normally-open main poles across the three contactors. Auxiliary contacts are pre-configured: 1 NC + 1 NO on the star contactor, 2 NC + 1 NO on the line contactor, and 1 NC + 2 NO on the delta contactor. This covers the standard interlocking and status feedback for a star delta start sequence without adding auxiliary blocks.

The LC3F400M7 complies with EN 60947-1, EN 60947-4-1, IEC 60947-4-1, IEC 60947-1, and JIS C8201-4-1. These are the core standards for low-voltage switchgear and motor starters — covering construction, performance, and test requirements for global acceptance.

Frequently asked questions

What are the key motor power ratings for the LC3F400M7?

Motor power is voltage-dependent: 185 kW at 220/230 V AC, 315 kW at 380/400 V AC, 355 kW at 415 V AC, and 375 kW at 440 V AC, all at 50/60 Hz in AC-3 duty.

What is the control voltage and coil type?

The control circuit is AC 50/60 Hz at 220/230 V AC. The coil operates between 0.85 and 1.1 Uc for pick-up and drops out between 0.35 and 0.55 Uc.

What standards does the LC3F400M7 comply with?

It complies with EN 60947-1, EN 60947-4-1, IEC 60947-4-1, IEC 60947-1, and JIS C8201-4-1.

What are the physical dimensions and mounting requirements?

Dimensions are 28.5 in (725 mm) wide, 10.9 in (276 mm) deep, and 7.09 in (180 mm) high. Mounting is plate-mount only — not DIN rail. Power connections use M10 bolts.