Specifications

Identification

LP1D40004MW — Identification
ParameterValue
Product / component typeContactor
ApplicationResistive load

Ratings & Performance

LP1D40004MW — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1 AC-3 AC-3e AC-4

Contacts & Poles

LP1D40004MW — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LP1D40004MW — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529 IP2X conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessShocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Approvals

LP1D40004MW — Approvals
ParameterValue
StandardsIEC 60947-1 EN 60947-4-1 BS 5424 IEC 60947-4-1 EN 60947-1 NF C 63-110 JEM 1038 VDE 0660

Mechanical

LP1D40004MW — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth182 mm

Product details

The LP1D40004MW is a 4-pole contactor from the TeSys Deca range, rated for 60 A in AC-1 duty at 440 V with a 220 V DC coil. It's designed for resistive load switching and carries utilisation categories AC-1, AC-3, AC-3e, and AC-4, making it suitable for motor starting and general switching in control panels. Mounts on plate or rail, with IP2X finger protection per IEC 60529 and VDE 0106, so it's safe for open-panel installations where accidental contact is a concern. Compliance covers IEC 60947-1, EN 60947-4-1, BS 5424, and several national standards.

The AC-1 rating of 60 A at 440 V governs resistive loads (heaters, lighting). For motor duty, the AC-3 rating will be lower — that's the figure to check against your motor's full-load current. The 220 V DC coil is unusual for this frame size; ensure your control supply matches exactly, as DC coils have a narrower pick-up/drop-out band than AC. If your application sequences contactors, this timing matters for interlocking. Operating altitude of 3000 m without derating covers most installations outside high-altitude mining or mountain sites. Above that, expect reduced dielectric withstand and thermal capacity.

Integration notes

Dimensions are 85 mm wide, 127 mm high, 182 mm deep — a standard TeSys Deca 4-pole footprint. Plate or rail mount, so it retrofits into existing Deca backplates or DIN-rail enclosures. The 182 mm depth is the front-to-back projection including arc chutes; verify clearance against enclosure doors or busbars. Ambient operating range is -40 to 60 °C, with derating required above 60 °C up to 70 °C. Storage range extends to -60 to 80 °C.

Frequently asked questions

What are the key ratings for this contactor?

4 poles, AC-1 rating of 60 A at 440 V, coil 220 V DC. Utilisation categories include AC-1, AC-3, AC-3e, and AC-4. IP2X finger protection, operating temperature -40 to 60 °C.

What compliance documentation is available for this part?

It complies with IEC 60947-1, EN 60947-4-1, BS 5424, and several other national standards. Fire resistance is 850 °C per IEC 60695-2-1, and flame retardance is UL 94 V1.

MPN
LP1D40004MW