Skip to main content
Schneider Electric LP1D40008BD

Schneider Electric LP1D40008BD TeSys Deca Contactor, 4P, AC-

MPNLP1D40008BD
Active

Schneider Electric TeSys Deca LP1D40008BD 4-pole contactor, AC-1 rated 60 A for resistive loads, 7.2 in depth, built-in DC coil suppression.

$489.00Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

LP1D40008BD key specifications
ParameterValue
Range of productTeSys Deca
Control circuit typeDC DC standard
Product or component typeContactor
Coil voltage24 V DC
VoltagePower circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL
Control circuit voltage limits0.1...0.3 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational DC 1...1.1 Uc (131...158 °F (55...70 °C)):operational DC
[Ue] rated operational voltagePower circuit <= 1000 V AC 25...400 Hz
[Uimp] rated impulse withstand voltage6 kV IEC 60947
[Icw] rated short-time withstand current72 A 104 °F (40 °C) - 10 min for power circuit 165 A 104 °F (40 °C) - 1 min for power circuit 320 A 104 °F (40 °C) - 10 s for power circuit 720 A 104 °F (40 °C) - 1 s for power circuit
Breaking capacity800 A at 440 V for power circuit conforming to IEC 60947
[Ie] rated operational current60 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit
[Ith] conventional free air thermal current60 A (at 140 °F (60 °C)) for power circuit

All specifications

LP1D40008BD additional specifications
ParameterValue
Inrush power in22 W 68 °F (20 °C))
Power dissipation per pole5.4 W AC-1
Hold-in power consumption in22 W 68 °F (20 °C)
Poles description4P
Pole contact composition2 NO + 2 NC
Utilisation categoryAC-1
IP degree of protectionIP20 front face IEC 60529
Mounting supportPlate Rail
Connections - terminalsPower circuit: screw clamp terminals 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.004...0.02 in² (2.5...16 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.004...0.02 in² (2.5...10 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: solid Power circuit: screw clamp terminals 2 0.004...0.02 in² (2.5...16 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid
Pollution degree3
Operating altitude0...9842.52 ft (0...3000 m)
Depth7.2 in (182 mm)
Width3.3 in (85 mm)
Height5 in (127 mm)
Electrical durability1.4 Mcycles 60 A AC-1 <= 440 V
Mechanical durability10 Mcycles
StandardsCSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1
RangeTeSys
CategoryUS10I1222358
Time constant75 ms
Operating time4...19 ms opening 12...26 ms closing
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Fire resistance1562 °F (850 °C) IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
Protective coverWith
Average impedance1.5 mOhm - Ith 60 A 50 Hz for power circuit
Device short nameLP1D
Tightening torquePower circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04...0.05 in² (25...35 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002...0.04 in² (1...25 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Compatibility codeLP1D
Overvoltage categoryIII
Contactor applicationResistive load
Mechanical robustnessShocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5...300 Hz) Vibrations contactor closed 4 Gn, 5...300 Hz)
Associated fuse rating80 A gG at 80 A gG at <= 690 V coordination type 2 for power circuit
Maximum operating rate3600 cyc/h at 60 °C
Safety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity800 A at 440 V for power circuit conforming to IEC 60947
Permissible ambient air temperature around the device-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating

Product details

TeSys Deca 4-pole for resistive loads

That means it's the right call for heater banks, lighting contactors, and resistive oven control, not for across-the-line motor starting. The built-in bidirectional peak limiting diode suppressor on the DC coil saves you an external snubber and one DIN slot. Rated AC-1 at 60 A with an electrical durability of 1.4 million cycles at that load, it'll outlast most panels on a cycling oven or furnace line. Mechanical durability hits 10 million cycles, so moving parts stay tight through the machine's service life. Operating time is 4 to 19 ms opening, 12 to 26 ms closing – fast enough for interlock sequencing without hammering the contacts. And with a breaking capacity of 800 A at 440 V, it clears a fault if something goes wrong downstream.

Pollution degree 3 rating means it shrugs off conductive dust and factory air. Power circuit terminals accept wire from 2.5 to 25 mm² flexible or solid, with screw clamp torque at 8 N·m (70.8 lbf·in). Control circuit terminals are smaller – 1 to 4 mm², torqued to 1.7 N·m. Tighten them with a #2 Pozidriv or flathead; the strip length is 8 mm on the control side.

Frequently asked questions

What is the depth of the LP1D40008BD?

The contactor is 7.2 inches (182 mm) deep, which is standard for the TeSys Deca frame size.

What coil suppression is built in?

There is a built-in bidirectional peak limiting diode suppressor on the DC coil, so no external flyback diode is needed.

MPN