Schneider Electric LP1D65004FW — Contactors

TeSys LP1D65004FW Contactor, 4P AC-1 80A, 110 VDC Coil

MPNLP1D65004FW
Active

Schneider Electric TeSys Deca LP1D65004FW, 4-pole contactor, AC-1 440V 80 A, 110 V DC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP1D65004FW — Identification
ParameterValue
Product / component typeContactor
ApplicationResistive load
LP1D65004FW — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1 AC-3 AC-3e AC-4
LP1D65004FW — Contacts & Poles
ParameterValue
Pole configuration4P
LP1D65004FW — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529 IP2X conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessShocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94
LP1D65004FW — Approvals
ParameterValue
StandardsIEC 60947-4-1 BS 5424 VDE 0660 EN 60947-4-1 NF C 63-110 EN 60947-1 IEC 60947-1 JEM 1038
LP1D65004FW — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth182 mm

Product details

The Schneider Electric LP1D65004FW is a 4-pole contactor from the TeSys Deca range, rated for 80 A in AC-1 utilisation category at 440 V with a 110 V DC coil. It is designed for resistive load switching and carries utilisation categories AC-1, AC-3, AC-3e, and AC-4, meaning it can handle both resistive and motor loads up to its rated current, though the AC-3 motor rating is not separately listed here — the AC-1 figure is the one to size against for resistive duty.

Mounts on plate or rail (DIN rail compatible), so it fits standard panel layouts. Dimensions are 182 mm deep, 85 mm wide, 127 mm tall — the 85 mm width is the key panel-space figure when laying out multiple contactors side by side.

Standards and environmental limits

Compliant with IEC 60947-4-1, EN 60947-4-1, BS 5424, VDE 0660, and JEM 1038 — the core contactor standard for motor starting and switching. Fire resistance rated to 850 °C per IEC 60695-2-1, flame retardance V1 per UL 94. Operates from -40 to 60 °C ambient, with derating above 60 °C up to 70 °C; storage range is -60 to 80 °C.

Frequently asked questions

What are the key ratings for this contactor?

It is a 4-pole contactor rated 80 A in AC-1 utilisation category at 440 V, with a 110 V DC coil. It also carries AC-3, AC-3e, and AC-4 categories for motor loads. Dimensions are 182 mm deep, 85 mm wide, 127 mm tall.

What standards does this contactor comply with?

It complies with IEC 60947-4-1, EN 60947-4-1, BS 5424, VDE 0660, NF C 63-110, JEM 1038, and has fire resistance to 850 °C per IEC 60695-2-1 and flame retardance V1 per UL 94.

MPN
LP1D65004FW