TeSys LP1D65004UD Contactor, 4P, AC-1 80A, 250 VDC Coil

MPNLP1D65004UD
Active

Schneider Electric TeSys Deca LP1D, 4-pole contactor, AC-1 440V 80 A, coil 250 V DC, IP2X.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LP1D65004UD — Identification
ParameterValue
Product / component typeContactor
ApplicationResistive load

Ratings & Performance

LP1D65004UD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1 AC-3 AC-3e AC-4

Contacts & Poles

LP1D65004UD — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LP1D65004UD — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529 IP2X conforming to VDE 0106
Operating altitude3000 m without derating
Mechanical robustnessShocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
Flame retardanceV1 conforming to UL 94

Approvals

LP1D65004UD — Approvals
ParameterValue
StandardsJEM 1038 NF C 63-110 VDE 0660 EN 60947-4-1 IEC 60947-4-1 EN 60947-1 BS 5424 IEC 60947-1

Mechanical

LP1D65004UD — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth182 mm

Product details

The LP1D65004UD is a TeSys Deca LP1D-series 4-pole contactor rated for resistive loads at AC-1 80 A on a 440 V power circuit, with a 250 V DC coil. It carries utilisation categories AC-1, AC-3, AC-3e, and AC-4, meaning it handles resistive, standard motor starting, high-efficiency motor, and plugging/inching duty respectively — the AC-1 80 A figure governs continuous resistive loads, while motor switching current will be lower per the AC-3 derating curve.

Certified to IEC 60947-4-1, EN 60947-4-1, VDE 0660, BS 5424, JEM 1038, and NF C 63-110 — the core contactor standard for motor starters and switching duties across European and Asian jurisdictions. Flame retardance rated V1 per UL 94, fire resistance at 850 °C per IEC 60695-2-1, and protective treatment TH (pollution degree 3) per IEC 60068 for tropical/humid environments.

Mounts on rail or plate. Dimensions 182 mm deep × 85 mm wide × 127 mm high — the 85 mm width is a standard 4-pole footprint for panel layout on a DIN rail or backplate. IP2X finger protection per IEC 60529 and VDE 0106, so the contactor body prevents finger access to live parts but is not sealed against dust or moisture — suitable for enclosed panel installation, not washdown areas. Operates from -40 °C to 60 °C, with derating above 60 °C up to 70 °C; storage range -60 °C to 80 °C. Mechanical shock rated 10 Gn (open) and 15 Gn (closed), vibration 2 Gn (open) and 4 Gn (closed) over 5–300 Hz — robust for industrial panel mounting near rotating machinery.

Frequently asked questions

What are the key ratings for this contactor?

4-pole contactor rated AC-1 80 A at 440 V with a 250 V DC coil. Utilisation categories AC-1, AC-3, AC-3e, AC-4. Dimensions 182 × 85 × 127 mm. IP2X finger protection. Operating temperature -40 to 60 °C.

What standards does the LP1D65004UD comply with?

Certified to IEC 60947-4-1, EN 60947-4-1, VDE 0660, BS 5424, JEM 1038, NF C 63-110. Flame retardance V1 per UL 94, fire resistance 850 °C per IEC 60695-2-1, protective treatment TH (pollution degree 3) per IEC 60068.

What is the depth and width of the LP1D65004UD?

Depth 182 mm, width 85 mm, height 127 mm. The 85 mm width is a standard 4-pole contactor footprint for DIN-rail or plate mounting.