Schneider Electric LP1K06105UD3 — Contactors

Schneider LP1K06105UD3 TeSys K Contactor, 6A, 250VDC Coil, O

MPNLP1K06105UD3
Obsolete

Schneider Electric TeSys K, LP1K06105UD3, 3-pole contactor, AC-3 6A at ≤440V, 250VDC coil, built-in diode suppression, obsolete status.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP1K06105UD3 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LP1K06105UD3 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LP1K06105UD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP1K06105UD3 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP1K06105UD3 — Mechanical
ParameterValue
Width1.8 in (45 mm)
Height2.3 in (58 mm)
Depth2.2 in (57 mm)
LP1K06105UD3 — Other specifications
ParameterValue
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Range of productTeSys K
Device short nameLP1K
Inrush power in3 W 68 °F (20 °C))
Compatibility codeLP1K
Pole contact composition3 NO
Hold-in power consumption in3 W 68 °F (20 °C)
[Ie] rated operational current6 A at 10 MOhm for signalling circuit

Product details

The LP1K06105UD3: This is a 3-pole contactor from the TeSys K series, rated 6 A operational current in AC-3 utilisation category up to 440 V. The AC-3 rating covers starting and switching of squirrel-cage motors — the 6 A figure maps to roughly 2.2 kW at 400 V three-phase. AC-4 rating also listed, meaning it can handle inching and plugging duty where the motor is reversed before stopping. The coil is 250 VDC with a built-in bidirectional peak limiting diode suppressor. That suppressor is already inside the contactor body — no external flyback diode needed across the coil terminals. Hold-in power consumption is 3 W at 20 °C. Physical footprint: 1.8 in wide, 2.3 in high, 2.2 in deep (45 x 58 x 57 mm). Pole contact composition is 3 NO (three normally-open main poles). One normally-open auxiliary contact is included on the front.

What to expect on a replacement search

Since this part is obsolete, the natural question is what fits the same footprint and coil voltage. The TeSys K frame shares its mounting and panel cut-out with later TeSys Deca and TeSys F contactors, but coil voltages differ — a 250 VDC coil is uncommon on newer ranges. Pin-compatible direct drop-in is unlikely without verifying the coil circuit. A parametric cross-reference by coil voltage and current rating is the practical path.

Frequently asked questions

What replaces the LP1K06105UD3?

No official successor order code is listed. The TeSys K frame is superseded by the TeSys Deca series, but a 250 VDC coil is uncommon on newer contactors. A parametric search matching 6 A AC-3 at 440 V with a 250 VDC coil is required — expect that the replacement may need an external coil suppression module if the new contactor lacks a built-in diode.

MPN