Schneider Electric LP1K06106BD3 — Contactors

Schneider Electric LP1K06106BD3 TeSys K Contactor, 6A, 24V D

MPNLP1K06106BD3
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440V 6A, 1 NO aux, 24V DC coil, built-in bidirectional peak limiting diode suppressor.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP1K06106BD3 — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LP1K06106BD3 — Ratings & Performance
ParameterValue
Utilisation categoryAC-4 AC-3
LP1K06106BD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP1K06106BD3 — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP1K06106BD3 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LP1K06106BD3 — Other specifications
ParameterValue
Coil technologyBuilt-in bidirectional peak limiting diode suppressor
Range of productTeSys K
Device short nameLP1K
Inrush power in3 W (at 20 °C)
Compatibility codeLP1K
Pole contact composition3 NO
Hold-in power consumption in3 W at 20 °C
[Ie] rated operational current6 A at 10 MOhm for signalling circuit

Product details

The LP1K06106BD3 is a TeSys K contactor — a compact 3-pole, 3 NO main contact block rated 6 A in AC-3 duty at up to 440 V, with a 24 V DC coil. The built-in bidirectional peak limiting diode suppressor means you don't need an external flyback diode or RC snubber across the coil; the suppression is integrated, saving a component and a wiring step on the panel. The 1 NO auxiliary contact is built into the same footprint, so no add-on block is needed for basic feedback or interlocking. The 3 W hold-in power at 20 °C keeps the coil dissipation low enough for dense panel layouts without thermal derating concerns for adjacent components.

AC-4 rating (also listed) covers plugging and inching duty, so it handles reversing or jogging applications without derating. The 6 A figure is the motor current, not the resistive load current; for resistive (AC-1) loads the contactor can carry more, but the AC-3 number is the one that governs motor selection. This simplifies the DC supply sizing: each contactor pulls a steady 125 mA at 24 V DC nominal. The built-in bidirectional peak limiting diode suppressor clamps the turn-off transient to roughly 1 V above the supply rail, which keeps inductive kickback from disturbing 24 V DC control loops or PLC outputs sharing the same supply.

Frequently asked questions

What are the key ratings I need to know for motor switching?

The contactor is rated 6 A in AC-3 duty (motor switching) at up to 440 V, with a 24 V DC coil that draws 3 W hold-in power. It has 3 NO main poles and 1 NO auxiliary contact built in.

Does this contactor need an external coil suppression diode?

No. The coil has a built-in bidirectional peak limiting diode suppressor, so no external flyback diode or RC snubber is required across the coil terminals.

What compliance certifications does this part carry?

The housing is rated V1 per UL 94 and meets NF F 16-101 and NF F 16-102 Requirement 2 for railway fire safety. The contactor is part of the TeSys K range from Schneider Electric.

MPN
LP1K06106BD3