Skip to main content
Schneider Electric LP1K09016BD — Contactors

Schneider Electric LP1K09016BD TeSys K Contactor, 9A AC-3, 2

MPNLP1K09016BD
Obsolete

Schneider Electric TeSys K contactor, 3P, AC-3 <=440V 9A, 1 NC aux, 24V DC coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LP1K09016BD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
LP1K09016BD — Ratings & Performance
ParameterValue
Utilisation categoryAC-3 AC-4 AC-1
LP1K09016BD — Contacts & Poles
ParameterValue
Pole configuration3P
LP1K09016BD — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP1K09016BD — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm
LP1K09016BD — Other specifications
ParameterValue
Range of productTeSys K
Device short nameLP1K
Inrush power in3 W (at 20 °C)
Compatibility codeLP1K
Pole contact composition3 NO
Hold-in power consumption in3 W at 20 °C
[Ie] rated operational current20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit

Product details

The Schneider Electric LP1K09016BD is a TeSys K three-pole contactor with a 24 V DC coil, one normally closed auxiliary contact, and a rated operational current of 9 A in AC-3 duty at up to 440 V. It also carries ratings for AC-4 (inching/jogging) and AC-1 (resistive) utilisation categories, with the AC-1 current rated at 20 A. The 45 mm wide body fits standard DIN-rail or panel-mount enclosures alongside other TeSys K motor-control components.

The 9 A AC-3 rating at 440 V governs motor switching — this contactor handles a standard 3-phase induction motor up to roughly 4 kW at 400 V. The 20 A AC-1 rating covers resistive loads like heaters. The 24 V DC coil draws 3 W holding power at 20 °C, so a standard 24 VDC control supply with 3 W per contactor capacity is sufficient. Flame retardance meets UL 94 V1 and NF F 16-101/102, which is required for rail and transit applications.

Frequently asked questions

What is the closest replacement for the LP1K09016BD?

No official successor order code is listed. A form-fit-function equivalent would need to match the 45 mm width, 3-pole configuration, 9 A AC-3 rating, 24 V DC coil, and 1 NC auxiliary contact. Check the spec line yourself against current TeSys K or TeSys Deca catalog numbers.

What compliance documentation does this part carry?

The enclosure material is rated V1 per UL 94 and also meets NF F 16-101 and NF F 16-102 flame-retardance requirements for rail rolling stock.

MPN
LP1K09016BD