Skip to main content
Schneider Electric LP1K09103JD — Contactors

Schneider TeSys K LP1K09103JD Contactor, 9A AC-3, 12V DC Coi

MPNLP1K09103JD
Active

Schneider Electric TeSys K contactor, 3P, AC-3 ≤440V, 9A, 1 NO aux, 12V DC coil, LP1K09103JD.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LP1K09103JD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys

Ratings & Performance

LP1K09103JD — Ratings & Performance
ParameterValue
Utilisation categoryAC-1 AC-4 AC-3

Contacts & Poles

LP1K09103JD — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LP1K09103JD — Environmental
ParameterValue
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

Mechanical

LP1K09103JD — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Other specifications

LP1K09103JD — Other specifications
ParameterValue
Range of productTeSys K
Device short nameLP1K
Inrush power in3 W (at 20 °C)
Compatibility codeLP1K
Pole contact composition3 NO
Hold-in power consumption in3 W at 20 °C
[Ie] rated operational current20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit

Product details

The Schneider Electric LP1K09103JD is a TeSys K series 3-pole contactor rated for 9 A in AC-3 duty at up to 440 V, with a 12 V DC coil. That AC-3 rating means it handles the high inrush of starting squirrel-cage motors — the 9 A figure is the continuous motor current it can switch, not the resistive load curve. Three normally-open main poles and one normally-open auxiliary contact (1 NO) are built in. The utilisation category list (AC-1, AC-3, AC-4) tells you it can also handle resistive loads (AC-1) and plugging/reversing duty (AC-4), but the 9 A AC-3 figure is the one that governs motor-switching applications. Flame retardance is rated V1 per UL 94, which means the housing self-extinguishes within a vertical burn test — relevant for panel builders who need to meet NF F 16-101 or 16-102 railway fire-smoke-toxicity requirements.

The 3P + 1 NO auxiliary arrangement is typical for a small motor starter or a feed interlock; the auxiliary contact can be wired into the PLC input for feedback without needing a separate block. The 12 V DC coil is common in 24 V DC control buses with a step-down regulator, or in battery-backed safety circuits where a lower coil voltage reduces arc energy on dropout.

Frequently asked questions

What are the key ratings I need to know?

Rated operational current is 9 A in AC-3 duty (motor switching) at ≤440 V, with a 12 V DC coil. The contactor also carries AC-1 (resistive) and AC-4 (plugging/reversing) ratings. Flame retardance is V1 per UL 94.

What compliance documentation does this brand provide?

The contactor carries UL 94 V-1 flame retardance certification, and the TeSys K series typically includes CE, CSA, and RoHS declarations. Specific documentation (RoHS, REACH, UL, IEC) is available from the manufacturer's product documentation portal.

What is the closest pin-compatible alternative in this component family?

Within the TeSys K range, the LP1K09103JD is a 3P contactor with 1 NO aux and a 12 V DC coil. A direct alternative with the same pole count and aux configuration but a different coil voltage (e.g., 24 V DC or 110 V AC) would be a different order code in the same LP1K family. No pin-compatible alternative with identical coil voltage exists as a separate order code — the LP1K09103JD is the specific variant for 12 V DC.

MPN
LP1K09103JD