Skip to main content
Schneider Electric LP1K120045BD — Contactors

Schneider TeSys K LP1K120045BD Contactor, 4P, 20A, 24V DC

MPNLP1K120045BD
Obsolete

Schneider TeSys K contactor, LP1K120045BD, 4P (4 NO), AC-1 rated 20 A at 690 V, 24 V DC coil, 57 mm depth.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LP1K120045BD — Identification
ParameterValue
Product / component typeContactor
Series / rangeTeSys
ApplicationResistive load

Ratings & Performance

LP1K120045BD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz
Utilisation categoryAC-1

Contacts & Poles

LP1K120045BD — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LP1K120045BD — Environmental
ParameterValue
Operating altitude2000 m without derating
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102

Approvals

LP1K120045BD — Approvals
ParameterValue
StandardsEN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1

Mechanical

LP1K120045BD — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth57 mm

Product details

The LP1K120045BD is a TeSys K contactor from Schneider, configured with 4 normally-open poles. It is rated for 20 A in AC-1 utilisation category (resistive loads) at up to 690 V AC, 50/60 Hz. The coil is 24 V DC, drawing about 3 W inrush and 3 W hold-in power at 20 °C.

For motor or inductive loads, you would need to derate to the AC-3 or AC-4 category; this contactor is specified only for AC-1 (resistive) duty, so it is not a direct fit for starting motors. The rated breaking capacity reaches 110 A at 440 V, 80 A at 500 V, and 70 A at 660–690 V per IEC 60947 — meaning it can interrupt fault currents up to those levels, which matters for coordination with upstream protection. Impulse withstand voltage is 8 kV, overvoltage category III, so it is rated for fixed-installation distribution panels.

Frequently asked questions

What are the key ratings for this contactor?

It is rated 20 A at 690 V AC in AC-1 (resistive) duty, with a 24 V DC coil. Breaking capacity is 110 A at 440 V, 80 A at 500 V, and 70 A at 660–690 V. Mechanical durability is 10 million cycles.

What standards does this contactor comply with?

It complies with EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. It also meets UL 94 V1 flame retardance and NF F 16-101/102 for railway applications.

MPN
LP1K120045BD