For motor loads (AC-3 duty), this unit is not rated — select a TeSys K variant with AC-3 utilisation category instead. The 4 NO pole configuration gives four independent switching paths, all closing on coil energisation, suited for three-phase plus neutral or four independent resistive circuits. Rated breaking capacity reaches 110 A at 440 V, 80 A at 500 V, and 70 A at 660…690 V per IEC 60947, so it interrupts fault currents well above its continuous rating. The rated making capacity is 144 A AC for the power circuit. Impulse withstand voltage is 8 kV (Uimp), and insulation voltage (Ui) is 690 V per IEC 60947-4-1, 600 V per UL 508 and CSA C22.2 No 14. Coil operating limits are 0.8…1.15 Uc for pick-up and 0.1…0.75 Uc for drop-out at under 50 °C. Operating time is 30…40 ms for coil energisation and NO closing, 10 ms for de-energisation and NO opening. Maximum operating rate is 3600 cycles per hour. Mechanical durability is 10 million cycles. For safety applications, B10d is 1,369,863 cycles with nominal load and 20,000,000 cycles with mechanical load per EN/ISO 13849-1.

Schneider TeSys K LP1K12004JD3 Contactor, 4P 4NO, 20A AC-1,
Schneider Electric TeSys K contactor, LP1K12004JD3, 4P (4 NO), AC-1 rated 20 A at ≤440 V, 12 V DC coil, 57 mm depth.
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Contactor |
| Series / range | TeSys |
| Application | Resistive load |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 690 V AC 50/60 Hz |
| Utilisation category | AC-1 |
| Parameter | Value |
|---|---|
| Pole configuration | 4P |
| Parameter | Value |
|---|---|
| Operating altitude | 2000 m without derating |
| Flame retardance | V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
| Parameter | Value |
|---|---|
| Standards | EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 |
| Parameter | Value |
|---|---|
| Width | 45 mm |
| Height | 58 mm |
| Depth | 57 mm |
Product details
Frequently asked questions
What are the key ratings I need to check for fit?
The critical ratings are: 4 poles (4 NO), AC-1 utilisation category, 20 A rated operational current at 690 V AC, 12 V DC coil with operating limits of 0.8…1.15 Uc pick-up and 0.1…0.75 Uc drop-out. Dimensions are 45 x 58 x 57 mm for DIN-rail or plate mounting.
What compliance documentation is available?
The contactor is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. The manufacturer provides RoHS, REACH, and UL/CSA/IEC compliance documentation upon request.