The 36 V DC coil suits control circuits common in panel installations. Rated for AC-1 (resistive), AC-3 (motor start/run), and AC-4 (plugging/inching) utilisation categories, so it covers both standard motor reversing and more demanding stop-start cycles. Altitude derating kicks in above 2000 m. Mechanical robustness is specified per IEC 60068-2-27: 15 Gn shock on Z axis when closed, 10 Gn when open — enough for most industrial environments but not extreme mobile applications.
If you need a drop-in replacement, a parametric cross-reference within the TeSys K family is possible, but pin compatibility and mounting footprint must be verified against your existing panel layout.
Spring-cage terminals accept 0.2–2.5 mm² solid or ferruled stranded; strip length of 8 mm avoids whiskers under the cage. The IP20 enclosure means no additional finger-duct clearance needed inside the panel. Flame retardance meets UL 94 V1 and NF F 16-101/102, so it passes rail and industrial fire-safety requirements. Protective treatment conforms to IEC 60068 and DIN 50016 for humidity and corrosion resistance — relevant if the panel sees condensation cycles.