Specifications

LP2K12013BD3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K12013BD3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LP2K12013BD3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K12013BD3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K12013BD3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The LP2K12013BD3 is a TeSys K reversing contactor from Schneider Electric, a 3-pole device rated for AC-3 motor switching at 12 A up to 440 V, with a 24 V DC coil and one NC auxiliary contact. Rated for AC-1 resistive loads and AC-3 motor control, this contactor handles the inrush and breaking of inductive loads typical of small conveyors, pumps, and fans. The 24 V DC coil is common in PLC-controlled panels where low-voltage control is preferred.

For a replacement, the official successor within the TeSys K family is the LP2K12013BD3 — same order code, same ratings — but since that's also obsolete, the practical path is to cross-reference to a current TeSys Deca or TeSys Giga reversing contactor with matching pole count, coil voltage, and AC-3 rating. The 57 mm depth and 90 mm width give a baseline for panel fit.

At 57 mm deep, 90 mm wide, and 58 mm tall, the LP2K12013BD3 fits a standard DIN-rail footprint. IP20 finger-safe protection (VDE 0106) means it's suitable for enclosed panels where operators might reach in. Flame retardance meets UL 94 V1 and NF F 16-101/102, so it passes rail and industrial fire-safety requirements.

Frequently asked questions

What is the closest alternative to LP2K12013BD3?

The official TeSys K successor carries the same order code, but since that is also obsolete, the practical replacement is a current TeSys Deca or TeSys Giga reversing contactor with matching pole count (3P), AC-3 rating (12 A at 440 V), and 24 V DC coil. Panel dimensions (57 mm deep, 90 mm wide) help with fit assessment.

What are the key ratings of LP2K12013BD3?

3-pole reversing contactor, AC-3 rated 12 A at 440 V, 24 V DC coil, one NC auxiliary contact. IP20 finger-safe, UL 94 V1 flame retardance, operating temperature -25 to 50 °C.