Skip to main content
Schneider Electric LP2K1201GD — Contactors

Schneider Electric LP2K1201GD TeSys K reversing contactor, 3

MPNLP2K1201GD
Obsolete

Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 125 V DC coil, LP2K1201GD.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LP2K1201GD — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP2K1201GD — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-1 AC-4 AC-3
LP2K1201GD — Contacts & Poles
ParameterValue
Pole configuration3P
LP2K1201GD — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP2K1201GD — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

The coil is 125 V DC, and the contactor includes one normally closed auxiliary contact. The utilisation categories cover AC-1 (resistive loads), AC-3 (squirrel-cage motors), and AC-4 (plugging/inching). For a reversing contactor, AC-4 duty is particularly relevant — it handles the high electrical stress during motor reversal without derating below the 12 A threshold at 440 V. The contactor is rated IP20 per VDE 0106, so it is suitable for installation inside an enclosure where fingers or tools are kept out.

Mechanical and environmental ratings

The contactor is rated for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6: 15 Gn for 11 ms on Z axis when closed, 10 Gn when open. Vibration withstand is 4 Gn closed, 2 Gn open across 5–300 Hz. This makes it suitable for installation on machinery or in panels subject to moderate mechanical stress. Flame retardance is V1 per UL 94, and it also meets NF F 16-101 and NF F 16-102 requirements — relevant for rail or public-transport applications where fire safety is audited. Operating altitude is 2000 m without derating, which covers most industrial sites. Protective treatment is TC per IEC 60068 and DIN 50016, indicating a tropicalised coating for humid or corrosive environments.

Frequently asked questions

What are the key ratings of the LP2K1201GD?

It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 125 V DC coil and one NC auxiliary contact. It covers AC-1 and AC-4 utilisation categories as well.

What compliance documentation is available for this part?

The part carries IP20 per VDE 0106, flame retardance V1 per UL 94, and meets NF F 16-101 and NF F 16-102 for rail fire safety. Shock and vibration ratings are per IEC 60068-2-27 and IEC 60068-2-6.

MPN