Skip to main content
Schneider Electric LP5K12105JW3 — Contactors

Schneider Electric TeSys K LP5K12105JW3 reversing contactor,

MPNLP5K12105JW3
Active

Schneider Electric TeSys K reversing contactor, LP5K12105JW3, 3P, AC-3 ≤440 V 12 A, 1 NO, 12 V DC coil, IP20, preassembled with reversing power busbar.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LP5K12105JW3 — Identification
ParameterValue
Product / component typeReversing contactor
Series / rangeTeSys
ApplicationResistive load Motor control
LP5K12105JW3 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit
Utilisation categoryAC-4 AC-1 AC-3
LP5K12105JW3 — Contacts & Poles
ParameterValue
Pole configuration3P
LP5K12105JW3 — Environmental
ParameterValue
IP degree of protectionIP20 conforming to VDE 0106
Operating altitude2000 m without derating
Mechanical robustnessShocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Protective treatment / pollution degreeTC conforming to IEC 60068 TC conforming to DIN 50016
Flame retardanceV1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102
LP5K12105JW3 — Mechanical
ParameterValue
Width90 mm
Height58 mm
Depth57 mm

Product details

It's rated AC-3 at 12 A up to 440 V, which means it's sized for switching three-phase motor loads in that current range: conveyors, pumps, small crusher feeders. The coil pulls in on 12 V DC, so it's a straight fit for a 12 VDC control supply — common in mobile equipment or PLC-driven panels where you're running a 24 VDC bus with a step-down. AC-1 and AC-4 utilisation categories are also listed, so it covers resistive loads and plugging/inching duty as well.

Built to take the punishment of a mineral processing line

This contactor shrugs off the vibration you get on a crusher floor or a mill motor starter. It's rated for 4 Gn vibration closed and 2 Gn open over 5–300 Hz, and shock-tested to 15 Gn closed on the Z axis — all per IEC 60068-2-6 and IEC 60068-2-27. That means it stays closed under the hammering of a conveyor start or a nearby breaker trip. The IP20 finger-safe housing (per VDE 0106) keeps dust and tools out of the live terminals, but it's meant for a panel — not open washdown. Flame retardance is V1 per UL 94, so it meets the self-extinguishing requirement for enclosed industrial control gear. Operating altitude is 2000 m without derating, which covers most mine sites and high-country installations.

Frequently asked questions

What are the key ratings of LP5K12105JW3?

It is a three-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 12 V DC coil. It also covers AC-1 and AC-4 utilisation categories. The housing is IP20, and it withstands vibration up to 4 Gn closed and shock up to 15 Gn on the Z axis.

What compliance documentation is available for this part?

The contactor carries a V1 flame-retardance rating per UL 94, and the IP20 protection is per VDE 0106. It also meets NF F 16-101 and NF F 16-102 for flame retardance. Standard Schneider Electric compliance documentation (RoHS, REACH, UL, IEC) is available from the manufacturer.

MPN
LP5K12105JW3