Skip to main content
Schneider Electric LR3D3803

Schneider Electric LR3D3803

MPNLR3D3803
Obsolete

Thermal overload relay,TeSys Deca,62-80A,1NO+1NC,class10A,EverLink+springs

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LR3D3803 key specifications
ParameterValue
Control typeRed push-button stop Blue push-button reset
Network typeDC AC
Product or component typeNon differential thermal overload relay
Climatic withstandIACS E10
VoltagePower circuit 690 V IEC 60947-4-1 Power circuit 600 V UL 60947-4-1 Power circuit 600 V CSA C22.2 No 14
[Ue] rated operational voltage690 V AC 0...400 Hz power circuit IEC 60947-4-1
[Uimp] rated impulse withstand voltage6 kV
Permissible current0.95 A 380 V AC-15 signalling circuit 0.06 A 440 V DC-13 signalling circuit
[Ith] conventional free air thermal current5 A signalling circuit
Power dissipation per pole4.8 W
Network frequency0...400 Hz
Phase failure sensitivityTripping current 130 % of Ir on two phase, the last one at 0

All specifications

LR3D3803 additional specifications
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Mounting supportPlate, with terminal block LAD96560 on top Rail, with terminal block LAD96560 on top Direct mounting under contactor
Connections - terminalsPower circuit EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) flexible with cable end Power circuit EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) solid Control circuit spring terminals 1 0.002...0.004 in² (1...2.5 mm²) solid Power circuit EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) flexible Power circuit direct terminal link top Control circuit spring terminals 1 0.002...0.004 in² (1...2.5 mm²) flexible
Depth4.8 in (123 mm)
Width2.2 in (55 mm)
Height2.8 in (70 mm)
StandardsEN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5
RangeTeSys TeSys Deca
Category22347-CONTACTOR,D-LINE,OVERLOADS-NEW
Flame retardanceV1 conforming to UL 94
Device short nameLR3D
Relay applicationMotor protection
Tightening torquePower circuit 44.3 lbf.in (5 N.m) EverLink BTR screw connectors 0.04 in² (25 mm²) Power circuit 70.8 lbf.in (8 N.m) EverLink BTR screw connectors 0.05 in² (35 mm²)
Tripping threshold1.14 +/- 0.06 Ir IEC 60947-4-1
Dielectric strength1.89 kV 50 Hz IEC 60947-1
Mechanical robustnessShocks15 Gn for 11 ms IEC 60068-2-7 Vibrations3 GN IEC 60068-2-6
Associated fuse rating4 A gG for signalling circuit 4 A BS for signalling circuit
Thermal overload classClass 10A IEC 60947-4-1
Temperature compensation-4...140 °F (-20...60 °C)
Auxiliary contact composition1 NO + 1 NC
Ambient air temperature for storage-76...158 °F (-60...70 °C)
Thermal protection adjustment range62...80 A
Ambient air temperature for operation-4...140 °F (-20...60 °C) without derating IEC 60947-4-1
MPN
LR3D3803