Micrologic 6.0 X control unit - for drawout Masterpact MTZ1

$2,712.60 – $2,848.21Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LV847292 key specifications
ParameterValue
Display typeLCD display - 128 x 96 pixels
Network typeAC
Metering typeCurrent I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Reactive power Q, Q1, Q2, Q3 total Apparent power S, S1, S2, S3 total Power factor Active energy Ep IN/OUT/tot Reactive energy Eq IN/OUT/tot Apparent energy Es IN/OUT/tot Demand current I1, I2, I3, In, Iavg Demand power P, Q, S Frequency Phase sequence Earth leakage current Total current harmonic distortion THD (I) Total voltage harmonic distortion THD (V) Unbalance current Unbalance voltage
Protection typeOverload protection (long time) conforming to ANSI 49 Instantaneous short-circuit protection conforming to ANSI 50 Short time short-circuit protection conforming to ANSI 51 Earth fault conforming to ANSI 51N
Type of measurementPower meter
Product or component typeControl unit
Long time delay adjustment typeAdjustable in step of 0.5 s
Short-time delay adjustment typeAdjustable
Network and machine diagnosis typeSystem (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: test Protection test: test Selectivity test: test Trip context information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state
Ground-fault pick-up adjustment typeAdjustable
Ground-Fault time delay adjustment typeAdjustable
Instantaneous pick-up adjustment type iiAdjustable

All specifications

LV847292 additional specifications
ParameterValue
Measurement voltage208...828 V AC 50/60 Hz phase to phase 120...480 V AC 50/60 Hz phase to neutral
[Ue] rated operational voltage690 V AC, +/- 10 %
Network frequency50/60 Hz
Frequency measurement range40...70 Hz
Poles4P 3P
Protected poles description3P 3d 4P 3d 4P 3d + N/2 4P 4d 4P 3d + OSN
Communication port protocolBluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer conforming to ISO 15963 USB peer to peer 115 kbauds
Mounting modeDrawout
Mounting locationIndoor use only
Pollution degree3 conforming to IEC 60947-1
Relative humidity95 % at 55 °C conforming to IEC 60068-2-30
Operating altitude<= 5000 m with operational voltage derating 560 V AC
StandardsEN/IEC 60092-202 EN/IEC 60947-2 EN/IEC 60947-1 EN/IEC 60255-1 EN/IEC 61010-1
RangeMasterPacT
AccuracyClass 5: total current harmonic distortion THD (I) Class 0.5: unbalance voltage Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) Class 2: total voltage harmonic distortion THD (V)
Data recordingAlarm logs Maintenance logs Min/max of instantaneous values Time stamping Data logs Event logs
Thermal memoryYes
Trip unit rating400 A 630 A 800 A 1000 A 1250 A 1600 A
Device short nameMicroLogic 6.0 X
Energy managementMeasurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy
Device applicationEquipment protection, monitoring and control
Measurement accuracyCurrent I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A Neutral current IN: +/- 1 % Ground fault current Ig: +/- 5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 1 % Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % Apparent power S, S1, S2, S3, Sdemand: +/- 1 % Power factor: +/- 2 % Active energy Ep IN/OUT/tot: +/- 1 % Reactive energy Ep IN/OUT/tot: +/- 2 % Apparent energy Es IN/OUT/tot: +/- 1 % Frequency: +/- 0.005 Hz Earth leakage current: +/- 10 % Unbalance current: +/- 0.5 %
Measurement categoryCategory IV conforming to IEC 61010-2-30
Overvoltage categoryIV conforming to IEC 61010-1
Trip unit technologyElectronic
Neutral protection setting1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) No protection (4P 3d)
Circuit breaker applicationDistribution IEC standard
Environmental characteristicWet location not approved for use conforming to IEC 61010-1
Electromagnetic compatibilityElectrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Conducted and radiated emissions A conforming to CISPR 22
Trip unit protection functionsLSIG
Zone selective interlocking ZSIWith
Ambient air temperature for operation-25...70 °C (operating) -35 °C (for start-up of product)
[Tr] Long-Time delay adjustment range12.5...600 s at 1.5 x Ir 0.5...24 s at 6 x Ir 0.7...16.6 s at 7.2 x Ir
[Ir] long time pick-up adjustment range0.4...1 x In adjustable in step of 1 A
[Tsd] Short-Time delay adjustment range0.1...0.4 s I²t=on 0...0.4 s I²t=off
[Isd] short-time pick-up adjustment range1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or MasterPact MTZ mobile app
[Ig] ground-fault pick-up adjustment rangewith In > 400 A 0.2...1 x In adjustable in step of 1 or 10 A with In Ig enable on/off
[Ii] instantaneous pick-up adjustment range2...15 x In adjustable in step of 0.5 x In with embedded HMI 2...15 x In adjustable in step of 0.1 x In with Ecoreach software or MasterPact MTZ mobile app Ii enable on/off
[tg] ground-fault time delay adjustment range0.1...0.4 s I²t=on 0...0.4 s I²t=off
[Li mode] instantaneous delay adjustment range0 ms in fast 20 ms in standard
MPN
LV847292