Skip to main content
Schneider Electric SOL40N3E160 — Miniature Circuit Breakers (MCB)

Schneider Electric SOL40N3E160 EasyPact Solar MCCB, 160A, 50

MPNSOL40N3E160
Active

Schneider Electric EasyPact Solar MCCB, 3P, 160 A at 40 °C, 50 kA at 800 V AC, LSI electronic trip, IP20, grey RAL 7015.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

SOL40N3E160 — Identification
ParameterValue
Product range (series)EasyPact Solar MCCB
Product/component typeCircuit breaker
Device applicationDistribution
SOL40N3E160 — Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)800 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)1250 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
SOL40N3E160 — Protection
ParameterValue
Trip unit technologyElectronic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)4000 cycles at 800 V In
Mechanical durability (cycles)20000 cycles
SOL40N3E160 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
SOL40N3E160 — Environmental
ParameterValue
Operating ambient temperature-20...70 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
SOL40N3E160 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
SOL40N3E160 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity50 kA Icu at 800 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity40 kA at 800 V AC 50/60 Hz conforming to EN/IEC 60947-2
SOL40N3E160 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.25...1 x In
Trip unit protection functionsLSI

Product details

The SOL40N3E160 is a 3-pole EasyPact Solar MCCB from Schneider Electric, rated 160 A at 40 °C with a 50 kA breaking capacity at 800 V AC. If your panel runs hotter, you'll need to derate — the electronic trip allows some adjustment, but the base rating is at 40 °C. The 800 V AC operational voltage (50/60 Hz) per IEC 60947-2 suits 480 V and 600 V class systems with headroom, and the 1250 V rated insulation voltage means the internal clearances handle the transients on ungrounded solar arrays.

Deployment context

This breaker is designed for backplate mounting — fixed, not plug-in. The 40 mm connection pitch and front-facing screw terminals make busbar and cable landing straightforward in a distribution panel. IP20 finger-safe protection means the front is touch-safe, but the terminals need to be inside an enclosure. Pollution degree 3 (IEC 60664-1) means it's rated for conductive pollution environments typical of industrial panels, not just clean office air. Mount it horizontally or vertically — both orientations are allowed per the spec. The toggle control gives a clear visual indication of the contact position, and the suitability for isolation (per IEC 60947-2) means you can use it as a disconnecting means for safe maintenance access.

What's in the box and documentation

Standards compliance covers EN/IEC 60947-1, 60947-2, and 60947-2 Annex H (the solar-specific annex for DC applications).

Frequently asked questions

What trip unit does SOL40N3E160 use?

It uses an electronic LSI trip unit (ETU type) providing adjustable overload protection (L), short-time delay protection (S), and instantaneous protection (I), with thermal memory to prevent nuisance tripping on repeated overloads.

What compliance documentation does this brand provide for SOL40N3E160?

The SOL40N3E160 is certified to EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H (solar DC applications). It carries suitability for isolation per IEC 60947-2 and is rated overvoltage category III, pollution degree 3.

MPN