Schneider Electric TA1AD4L8004TPE — Disconnect Switches

Schneider Electric TA1AD4L8004TPE TransferPacT ATS, 800 A, 4

MPNTA1AD4L8004TPE
Active

Schneider Electric TransferPacT TA1AD4L8004TPE, automatic transfer switch, 800 A, 4 poles, AC-33B, IEC 60947-6-1, fixed plate mount.

$10,233.91Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

TA1AD4L8004TPE — Electrical
ParameterValue
Rated operational voltage [Ue]400 V AC 50/60 Hz
TA1AD4L8004TPE — Protection & Switching
ParameterValue
Poles description4P
Locking / padlockingPadlock in OFF position
TA1AD4L8004TPE — Mechanical
ParameterValue
Mounting supportPlate
Width540 mm
Height391 mm
Depth383.5 mm
TA1AD4L8004TPE — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
TA1AD4L8004TPE — Approvals
ParameterValue
StandardsIEC 60947-6-1
TA1AD4L8004TPE — Identification
ParameterValue
Product/component typeAutomatic transfer switch

Product details

TransferPacT TA1AD4L8004TPE — 800 A automatic transfer switch, AC-33B

The Schneider Electric TA1AD4L8004TPE is an 800 A automatic transfer switch from the TransferPacT range, built to IEC 60947-6-1 for change-of-supply-source applications. Rated operational current is 800 A at 400 V AC 50/60 Hz, with an AC-33B utilization category covering motor, resistive, and mixed loads including inrush — the rating that governs real-world switching duty, not just the thermal continuous number. Four poles (4P) with mechanical interlocking ensure the normal and emergency sources never close simultaneously. The PC-class switch-disconnector is rated for isolation, with a visible contact position indicator and three contact positions (I, 0, II). Lockout provision in OFF position via padlock.

Withstand and making capacity — selectivity headroom

Short-time withstand current (Icw) is 50 kA for 0.5 s and 70 kA for 0.1 s, giving the coordination engineer room to size upstream protection for selective tripping. Short-circuit making capacity (Icm) reaches 105 kA for the switch-disconnector alone, or 154 kA with an upstream protection circuit breaker. Rated impulse withstand voltage (Uimp) is 12 kV on the switch, 6 kV on the controller.

Integration — plate mount, screwed connections, LCD interface

Fixed plate mounting with a 115 mm connection pitch. Upside and downside connections are both screwed type — expect lug-style terminations for the 800 A conductors. Dimensions: 540 mm wide × 391 mm high × 383.5 mm deep. Front face achieves IP40 in auto mode; inside the enclosure, IP20 in manual mode. Automatic or manual operating mode selectable via the LCD screen interface. Signal contacts configurable as 1 NO + 2 NC or 1 NC + 2 NO or 2 NO — order the variant with the auxiliary contact arrangement your BOM requires. Mechanical durability rated at 10,000 cycles.

Frequently asked questions

Where can I buy TA1AD4L8004TPE and get a price?

The TA1AD4L8004TPE is sourced and quoted to order against an RFQ. Submit a request for current availability and pricing.

What is the rated operational current of TA1AD4L8004TPE?

The TA1AD4L8004TPE is rated for 800 A operational current (Ie) at 400 V AC 50/60 Hz, with a conventional free-air thermal current (Ith) of 800 A at 60 °C.

What standard does TA1AD4L8004TPE comply with?

The TA1AD4L8004TPE complies with IEC 60947-6-1, the standard for automatic transfer switches.

MPN
TA1AD4L8004TPE