Skip to main content
Schneider Electric TPRSS080

Schneider Electric TPRSS080

MPNTPRSS080
Active

SIL motor starter, TeSys island, 80A at AC-1, 66A at AC-3, 37kW, 40hp, DOL type

$806.26 – $901.25Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

TPRSS080 key specifications
ParameterValue
Monitoring typeTime device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module
Protection typeThermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Phase sequence Rapid restart lockout Phase loss Phase reversal Phase unbalance Ground current
Motor starter typeDirect on line
Product or component typeSIL motor starter
Coil voltage24 V DC supplied by the bus coupler
Voltage690 V IEC 60947-4-1 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1
[Ue] rated operational voltage<= 690 V AC 47...63 Hz
[Uimp] rated impulse withstand voltage6 kV IEC 60947-1
[Icw] rated short-time withstand current900 A 104 °F (40 °C) - 1 s 520 A 104 °F (40 °C) - 10 s 260 A 104 °F (40 °C) - 1 min 110 A 104 °F (40 °C) - 10 min
Current consumption80 mA contactor sealed 500 mA contactor closing
Breaking capacity1000 A at 440 V conforming to IEC 60947
[Ie] rated operational current66 A (at 80 A (at <122 °F (50 °C)) at <= 440 V AC-1

All specifications

TPRSS080 additional specifications
ParameterValue
[Ith] conventional free air thermal current80 A (at 122 °F (50 °C))
Motor power18.5 kW at 230 V 50 Hz (AC-3) 37 kW at 380...415 V 50 Hz (AC-3) 37 kW at 440 V 50 Hz (AC-3) 37 kW at 500 V 50 Hz (AC-3) 37 kW at 690 V 50 Hz (AC-3)
Power dissipation in21.4 W at Ie AC-3
Motor power HP (UL (CSA))5 hp at 120 V AC 60 Hz for 1 phase motors 10 hp at 240 V AC 60 Hz for 1 phase motors 20 hp at 208 V AC 60 Hz for 3 phase motors 20 hp at 240 V AC 60 Hz for 3 phase motors 40 hp at 480 V AC 60 Hz for 3 phase motors 50 hp at 600 V AC 60 Hz for 3 phase motors
Power dissipation per pole6.5 W AC-3 9.6 W AC-1
Poles description3P 3 NO
Utilisation categoryAC-1 AC-2 AC-3 AC-4 AC-3e
IP degree of protectionIP20
Mounting modeHorizontal and vertical 35 mm symmetrical DIN rail)
Connections - terminalsEverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) AWG 16...AWG 2)rigid EverLink BTR screw connectors 2 0.002...0.04 in² (1...25 mm²) AWG 16...AWG 4)rigid EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) AWG 16...AWG 2)flexible without cable end EverLink BTR screw connectors 2 0.002...0.04 in² (1...25 mm²) AWG 16...AWG 4)flexible without cable end EverLink BTR screw connectors 1 0.002...0.05 in² (1...35 mm²) AWG 16...AWG 2)flexible with cable end EverLink BTR screw connectors 2 0.002...0.04 in² (1...25 mm²) AWG 16...AWG 4)flexible with cable end
Pollution degree2
Shock resistance15 gn 11 ms) IEC 60068-2-27
Relative humidity5...95 %
Operating altitude0...6561.68 ft (0...2000 m) without derating
Vibration resistance1.5 mm peak to peak 3...13 Hz) IEC 60068-2-6 1 gn 13...200 Hz) IEC 60068-2-6
Depth4.9 in (125 mm)
Width2.2 in (55 mm)
Height6.6 in (167 mm)
Electrical durability0.75 Mcycles 66 A AC-3 440 V 0.5 Mcycles 80 A AC-1 440 V
Mechanical durability6 Mcycles
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
RangeTeSys
ResetRemotely or automatically
CategoryUS10I1222352
Operating time< 80 ms closing < 80 ms opening
Fire resistance1760 °F (960 °C) UL 94 1562 °F (850 °C) IEC 60695-2-1 1202 °F (650 °C) IEC 60695-2-12
Safety functionSafe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module Safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module
Local signalling1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)
Average impedance1.5 mOhm - Ith 80 A 50 Hz
Device short nameTPRSS
Tightening torque44.3 lbf.in (5 N.m) 0.002...0.04 in² (1...25 mm²) hexagonal 0.2 in (4 mm) 70.8 lbf.in (8 N.m) 0.04...0.05 in² (25...35 mm²) hexagonal 0.2 in (4 mm)
Function availableUpstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module Safe stop function available when connected with a TPRSM module
Device presentationDirect starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler
Overvoltage categoryIII
Protective treatmentTC
Maximum operating rate3600 cyc/mn AC-3
SIL ratingSIL 2 conforming to IEC 61508 in single channel system architecture SILCL 2 conforming to IEC 62061 in single channel system architecture PL = d category 2 conforming to ISO 13849-1 in single channel system architecture
Thermal overload classClass 5...30
Safety performance levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Irms rated making capacity1000 A at 440 V conforming to IEC 60947
Electromagnetic compatibilityElectrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Ambient air temperature for storage-13...158 °F (-25...70 °C)
Thermal protection adjustment range4...80 A
Ambient air temperature for operation14...122 °F (-10...50 °C) without derating 122...140 °F (50...60 °C) with current derating
MPN
TPRSS080