VW3A7103 resistance braking unit, 300 kW 690 V, obsolete

MPNVW3A7103
Obsolete

Schneider Electric VW3A7103 resistance braking unit, 300 kW permanent braking power at 690 V, 450 kW maximum, IP20, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

VW3A7103 — Environmental
ParameterValue
IP protection ratingIP20
Operating ambient temperature-10...50 °C
Storage ambient temperature-25...70 °C
Operating altitude1000...2260 m 1 % per 100 m
VW3A7103 — Other specifications
ParameterValue
Load factor0.05 for 450 kW at constant power and at engage threshold 0.15 for 400 kW at constant power and at engage threshold 0.5 for 350 kW at constant power and at engage threshold
Thermal losses650 W
Protection typeIntegrated thermal protection by thermal probe
Pollution degree2 conforming to EN 50178
Operating positionVertical
Activation threshold1075 V DC +/- 1 %
Vibration resistance0.2 gn
Maximum braking power450 kW
Volume of cooling air600 m3/h
Maximum DC bus voltage1100 V
Permanent braking power300 kW at 690 V (at constant power and at engage threshold)
Minimum resistor value to associate2 Ohm

Product details

The VW3A7103 is a resistance braking unit rated for 300 kW permanent braking power at 690 V, with a maximum braking capacity of 450 kW. It is designed for use with variable speed drives to dissipate regenerative energy from decelerating motors, typically on high-inertia loads like centrifuges, conveyors, or large fans. The unit activates at a DC bus threshold of 1075 V DC (±1 %) and can handle a maximum DC bus voltage of 1100 V. The minimum external resistor value to associate is 2 Ohm. Thermal losses are 650 W, requiring 600 m³/h of cooling air. Operating ambient temperature range is -10 to 50 °C, storage -25 to 70 °C. Pollution degree 2 per EN 50178 (non-conductive pollution only). Mount vertically only.

Load factor and braking power profile

The unit supports three load-factor / engage-threshold settings: 0.05 for 450 kW at constant power, 0.15 for 400 kW, and 0.5 for 350 kW. These define the duty cycle — a lower load factor allows higher peak power but for a shorter duration. The permanent rating of 300 kW at 690 V is the continuous dissipation limit.

Frequently asked questions

What is VW3A7103's listed load factor?

The load factor settings are 0.05 for 450 kW at constant power and at engage threshold, 0.15 for 400 kW, and 0.5 for 350 kW. These define the duty-cycle capability for intermittent braking.

What are the thermal losses of VW3A7103?

Thermal losses are 650 W. The unit requires 600 m³/h of cooling air to dissipate this heat.