Schneider Electric XPSMCMC10804EG
MPNXPSMCMC10804EG
Active
Safety controller with embedded communication, Modicon MCM, 8 inputs 4 outputs, monitors expansion modules, screw
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Range of product | Modicon MCM |
| Discrete input type | Safety input NPN or PNP |
| Discrete output type | PNP or NPN |
| Product or component type | Safety controller CPU |
| Integrated connection type | Backplane expansion bus USB 2.0 port |
| Discrete input voltage | 24 V |
| Supply voltage | 24 V - 20...20 % DC |
| [Uimp] rated impulse withstand voltage | 4 kV IEC 61800-5-1 |
| Discrete input current | 100 mA |
| Discrete output current | 400 mA |
| Power dissipation in | 3 W |
| I/O channels | 8 digital input connection 4 digital interlock start/restart or external device monitoring |
All specifications
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 |
| Mounting support | Omega 35 mm DIN rail EN 50022 |
| Backplane connector | Without |
| Cable cross section | 0.0003...0.002 in² (0.2...1.5 mm²) - AWG 24...AWG 16 flexible without cable end 0.0003...0.004 in² (0.2...2.5 mm²) - AWG 24...AWG 14 flexible without cable end 0.0004...0.002 in² (0.25...1 mm²) - AWG 23...AWG 18 flexible with cable end, without bezel 0.0004...0.004 in² (0.25...2.5 mm²) - AWG 23...AWG 14 flexible with cable end, with bezel 0.0004...0.002 in² (0.25...1.5 mm²) - AWG 23...AWG 16 flexible with cable end, without bezel 0.0008...0.002 in² (0.5...1.5 mm²) - AWG 20...AWG 16 flexible with cable end, with double bezel 0.0003...0.002 in² (0.2...1 mm²) - AWG 24...AWG 18 solid without cable end 0.0003...0.004 in² (0.2...2.5 mm²) - AWG 24...AWG 14 solid without cable end |
| Electrical connection | Spring terminal |
| Connections - terminals | 6 captive spring terminals, removable terminal block |
| Pollution degree | 2 |
| Shock resistance | 10 gn 16 ms) 1000 shocks on each axis IEC 61496-1 |
| Relative humidity | 10...95 % |
| Vibration resistance | +/-0.35 mm (f= 10...55 Hz) conforming to IEC 61496-1 |
| Depth | 4.5 in (114.5 mm) |
| Width | 1.8 in (45 mm) |
| Height | 3.9 in (99 mm) |
| Standards | IEC 61496-1 ISO 13849-1 IEC 61508 IEC 61800-5-1 IEC 62061 |
| Category | US1SAF222477 |
| Insulation | 250 V AC between power supply and housing IEC 61800-5-1 |
| Safety level | Can reach category 4 ISO 13849-1 Can reach PL = e ISO 13849-1 Type 4 IEC 61496-1 SILCL 3 IEC 62061 Can reach SILCL 1 ISO 13849-1 |
| Service life | 20 year(s) |
| Inductive load | 2 mH |
| Quality labels | CE |
| Load capacitance | 0.82 µF |
| Local signalling | 1 LED green PWR power ON 1 LED green RUN RUN (status) 1 LED red E IN internal error 1 LED red E EX external error 1 LED orange COM communication 1 LED blue EN master enable 8 LEDs yellow IN input status 4 LEDs OUT output status 2 LEDs yellow RST restart signal 2 LEDs yellow STATUS output channel 1 LED green/red MS module status 1 LED green/red NS network status |
| Device short name | XPSMCM |
| Function of module | Emergency stop ISO 13850 Guard monitoring EN/ISO 14119 Enabling switch monitoring IEC 60947-5-1 Light curtain monitoring IEC 61496-1 Foot switch monitoring IEC 60947-5-1 Light curtain monitoring EN/ISO 14119 Switch monitoring EN 574 Two-hand control EN/ISO 14119 Safety mat monitoring IEC 61326-1 Switch monitoring IEC 61800-5-2 Muting function of light curtains IEC 61800-5-2 Safety time delays Counter functions |
| Overvoltage category | II |
| Data storage equipment | SD card optional) |
| Safety reliability data | high DC > 99 % |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 |
| Ambient air temperature for storage | -4...185 °F (-20...85 °C) |
| Synchronisation time between inputs | < 0.5 ms |
| Ambient air temperature for operation | 14...131 °F (-10...55 °C) |
MPN