It carries 3 normally-open instantaneous contacts and 0 normally-closed, rated 10 A in AC-12 duty — that's the resistive load curve for solenoid and relay loads at line voltage, so it handles the pilot-duty switching typical in a 24 VDC or 230 VAC control loop without derating concerns.
Contact ratings and switching
AC-12 rating at 10 A covers the resistive control loads — contactors, relays, solenoid valves — at 24 V through 230 V. For inductive DC switching, the 24 VDC rating is 10 A, dropping to 1 A at 110 VDC and 0.27 A at 220 VDC. The contacts are rated for 30 million mechanical operations typical, so in a cycling application like a conveyor interlock it outlasts the panel it's in. No leading, lagging, or make-before-break contacts — all three are standard instantaneous NO.
Shock rated at 10g / 5 ms and 5g / 10 ms, which covers most vibration profiles in pump skids and conveyor drives. Maximum operating altitude 2 000 m without derating.