Siemens 3RH1131-2AC00-0TK1 — Contactors

Siemens 3RH1131-2AC00-0TK1 SIRIUS Auxiliary Contactor, 10A A

MPN3RH1131-2AC00-0TK1

Siemens SIRIUS auxiliary contactor, size S00, 3RH1131-2AC00-0TK1, 3 NO + 0 NC, screw and snap-on mounting, rated 10 A at 24 V AC-12.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RH1131-2AC00-0TK1 — Identification
ParameterValue
Contactor frame sizeS00
3RH1131-2AC00-0TK1 — Ratings & Performance
ParameterValue
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 110 V1 A
Rated value @ 220 V0.27 A
3RH1131-2AC00-0TK1 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz32 V
3RH1131-2AC00-0TK1 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH1131-2AC00-0TK1 — Protection & Coordination
ParameterValue
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RH1131-2AC00-0TK1 — Connection & Mounting
ParameterValue
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
3RH1131-2AC00-0TK1 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH1131-2AC00-0TK1 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
3RH1131-2AC00-0TK1 — Mechanical
ParameterValue
Width45 mm
Height60 mm
Depth73 mm

Product details

SIRIUS auxiliary contactor for control-circuit switching

It carries a rated operating current of 10 A at 24 V under AC-12 duty, which covers resistive and solid-state loads typical in PLC and relay logic interfaces.

The AC-12 rating at 24 V (10 A) is the headline figure — it tells you the contactor can handle the inrush of a small contactor coil or a bank of indicator lamps without welding its contacts. For higher voltages the current drops: 6 A at 230 V, 3 A at 400 V, 1 A at 690 V, so the real-world ampacity depends on your control voltage. The contact configuration is 3 NO instantaneous contacts (no delayed, lagging, or make-before-break options). Solid wire capacity is 2x (0.25 to 2.5 mm²), adequate for standard control wiring.

Size S00 is the smallest Siemens contactor frame — 45 mm wide, 60 mm tall, 73 mm deep. It snaps onto the same DIN rail as the main contactor (e.g., 3RT10 series) and shares the same side-by-side zero-clearance spacing: no gap needed at the side for cooling. The auxiliary contactor is typically mounted directly alongside or below the main contactor to provide feedback to the PLC or to extend the contact count for multi-signal circuits.

Frequently asked questions

What are the key ratings for the 3RH1131-2AC00-0TK1?

Rated 10 A at 24 V AC-12, with derated currents at higher voltages (6 A at 230 V, 3 A at 400 V, 1 A at 690 V). It has 3 NO instantaneous contacts, mechanical endurance of 30 million cycles, and operates from -25 to +60 °C.

What is the physical size of the 3RH1131-2AC00-0TK1?

Size S00 frame: 45 mm wide, 60 mm tall, 73 mm deep. It mounts via screw or snap-on onto a DIN rail with zero side clearance needed.

Will the 3RH1131-2AC00-0TK1 drop into a panel specified for a 3RT1015-1AG61?

Both are size S00 contactors with the same DIN-rail footprint and side-by-side zero clearance, so the auxiliary block will physically fit in the same panel space. However, the 3RT1015-1AG61 is a main contactor with a coil; the 3RH1131 is an auxiliary contactor without a coil. They serve different functions — one switches power, the other switches control signals — so they are not direct substitutes without rewiring the control circuit.

MPN
3RH1131-2AC00-0TK1